Ultrafast capillary electrophoresis/mass spectrometry with adjustable porous tip for a rapid analysis of protein digest in about a minute. (16th December 2013)
- Record Type:
- Journal Article
- Title:
- Ultrafast capillary electrophoresis/mass spectrometry with adjustable porous tip for a rapid analysis of protein digest in about a minute. (16th December 2013)
- Main Title:
- Ultrafast capillary electrophoresis/mass spectrometry with adjustable porous tip for a rapid analysis of protein digest in about a minute
- Authors:
- Moini, Mehdi
Martinez, Ben - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="rcm6786-sec-0001" sec-type="section"> <title>RATIONALE</title> <p>This paper introduces a novel ultrafast capillary electrophoresis (UFCE) mass spectrometry (MS) method comprised of a short (&lt; 20 cm) and narrow (≤ 5 µm) capillary, with an integrated porous segment at the terminus of the capillary, for sheathless interfacing of CE to MS. The sheathless nature of the interface minimizes dead volume which is particularly important for ultrafast CE because of the small diameters of the capillaries.</p> </sec> <sec id="rcm6786-sec-0002" sec-type="section"> <title>METHODS</title> <p>The separation voltage across the capillary was set to produce an electric field of ≥1000 V/cm to provide an analysis time of approximately 1 min. For the analysis of peptides and protein digests, a background electrolyte containing 0.1% cationic polymer (polybrene or Poly‐E) in 0.1% acetic acid in water was used to prevent analyte–wall interaction.</p> </sec> <sec id="rcm6786-sec-0003" sec-type="section"> <title>RESULTS</title> <p>Uniquely, the porous tip of the capillary is adjustable. This allows the porous tip to be pulled inside the sheath liquid for sample stacking during injection, or sample focusing in isoelectric focusing (IEF), or, alternatively, pushed outside of the sheath liquid for electrospray ionization (ESI). The adjustable interface preserves electrical conductivity during electrokinetic<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="rcm6786-sec-0001" sec-type="section"> <title>RATIONALE</title> <p>This paper introduces a novel ultrafast capillary electrophoresis (UFCE) mass spectrometry (MS) method comprised of a short (&lt; 20 cm) and narrow (≤ 5 µm) capillary, with an integrated porous segment at the terminus of the capillary, for sheathless interfacing of CE to MS. The sheathless nature of the interface minimizes dead volume which is particularly important for ultrafast CE because of the small diameters of the capillaries.</p> </sec> <sec id="rcm6786-sec-0002" sec-type="section"> <title>METHODS</title> <p>The separation voltage across the capillary was set to produce an electric field of ≥1000 V/cm to provide an analysis time of approximately 1 min. For the analysis of peptides and protein digests, a background electrolyte containing 0.1% cationic polymer (polybrene or Poly‐E) in 0.1% acetic acid in water was used to prevent analyte–wall interaction.</p> </sec> <sec id="rcm6786-sec-0003" sec-type="section"> <title>RESULTS</title> <p>Uniquely, the porous tip of the capillary is adjustable. This allows the porous tip to be pulled inside the sheath liquid for sample stacking during injection, or sample focusing in isoelectric focusing (IEF), or, alternatively, pushed outside of the sheath liquid for electrospray ionization (ESI). The adjustable interface preserves electrical conductivity during electrokinetic injection with reverse electro‐osmotic flow. Therefore, pre‐concentration of analytes at the capillary inlet is achieved without the need to disassemble the interface, improving the throughput.</p> </sec> <sec id="rcm6786-sec-0004" sec-type="section"> <title>CONCLUSIONS</title> <p>As a proof of concept, the application of UFCE‐MS was demonstrated by the analysis of a peptide mixture and a protein digest in ~1 min. Copyright © 2013 John Wiley &amp; Sons, Ltd.</p> </sec> </abstract> … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 28:Number 3(2014)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 28:Number 3(2014)
- Issue Display:
- Volume 28, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 28
- Issue:
- 3
- Issue Sort Value:
- 2014-0028-0003-0000
- Page Start:
- 305
- Page End:
- 310
- Publication Date:
- 2013-12-16
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.6786 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3710.xml