- Title:
- Evaluation of Erytra® fully automated analyser for Routine Use in Transfusion Laboratory. Issue 1 (5th November 2013)
- Main Title:
- Evaluation of Erytra® fully automated analyser for Routine Use in Transfusion Laboratory
- Authors:
- Chang, C.
Brown, M.
Davies, L.
Pointon, L.
Brown, R.
Barker, D. - Abstract:
- <abstract abstract-type="main" id="tme12073-abs-0001"> <title>SUMMARY</title> <sec id="tme12073-sec-0001" sec-type="section"> <title>Objective</title> <p id="tme12073-para-0001">To evaluate efficiency and performance of Erytra® analyser in comparison to the reference platform of the NBT immunohaematology laboratory (Bio‐Rad ID‐System).</p> </sec> <sec id="tme12073-sec-0002" sec-type="section"> <title>Background</title> <p id="tme12073-para-0002">Moving to automation or semi‐automation is a major focus of transfusion centres. The Erytra® (Grifols) is a new fully automated walk‐away analyser with high volume processing capacity for pre‐transfusion testing, designed to be used with the unique 8‐column DG Gel® cards.</p> </sec> <sec id="tme12073-sec-0003" sec-type="section"> <title>Study Design and Methods</title> <p id="tme12073-para-0003">A total of 2201 immunohaematological tests (1041 ABO/D grouping, 1041 antibody screening, 51 antibody identification, 45 newborns (ABO/D and DAT) and 23 crossmatches were performed on 1160 donor/patient whole blood samples. Erytra®'s performance was assessed by means of a stress test replicating the routine work of a hospital laboratory.</p> </sec> <sec id="tme12073-sec-0004" sec-type="section"> <title>Results</title> <p id="tme12073-para-0004">Concordant results between the Erytra® and the reference method were obtained in 2195 (99·73 %) of the tests. There were only three discrepancies out of 6246 reactions (0·05%) in ABO/D grouping, all in<abstract abstract-type="main" id="tme12073-abs-0001"> <title>SUMMARY</title> <sec id="tme12073-sec-0001" sec-type="section"> <title>Objective</title> <p id="tme12073-para-0001">To evaluate efficiency and performance of Erytra® analyser in comparison to the reference platform of the NBT immunohaematology laboratory (Bio‐Rad ID‐System).</p> </sec> <sec id="tme12073-sec-0002" sec-type="section"> <title>Background</title> <p id="tme12073-para-0002">Moving to automation or semi‐automation is a major focus of transfusion centres. The Erytra® (Grifols) is a new fully automated walk‐away analyser with high volume processing capacity for pre‐transfusion testing, designed to be used with the unique 8‐column DG Gel® cards.</p> </sec> <sec id="tme12073-sec-0003" sec-type="section"> <title>Study Design and Methods</title> <p id="tme12073-para-0003">A total of 2201 immunohaematological tests (1041 ABO/D grouping, 1041 antibody screening, 51 antibody identification, 45 newborns (ABO/D and DAT) and 23 crossmatches were performed on 1160 donor/patient whole blood samples. Erytra®'s performance was assessed by means of a stress test replicating the routine work of a hospital laboratory.</p> </sec> <sec id="tme12073-sec-0004" sec-type="section"> <title>Results</title> <p id="tme12073-para-0004">Concordant results between the Erytra® and the reference method were obtained in 2195 (99·73 %) of the tests. There were only three discrepancies out of 6246 reactions (0·05%) in ABO/D grouping, all in the reverse group which did not mislead to group identification. Of the 1041 samples screened for antibody presence, Erytra® detected all the relevant antibodies [9 not detected weak prophylactic anti‐D were determined to be clinically nonsignificant (&lt;0·1 IU mL<sup>−1</sup>)] while Bio‐Rad ID‐System missed one anti‐e and one anti‐Jk<sup>a</sup>. Concordance for D grouping, crossmatching and newborns was 100%. Results of the simulated stress test exercise highlighted the capacity of Erytra® for absorbing into 4 h workloads equivalent to 24 h of routine.</p> </sec> <sec id="tme12073-sec-0005" sec-type="section"> <title>Conclusions</title> <p id="tme12073-para-0005">Grifols' Erytra® analyser showed reliable high sensitivity, velocity and capacity to cope with high workload in the immunohaematology laboratory routine.</p> </sec> </abstract> … (more)
- Is Part Of:
- Transfusion medicine. Volume 24:Issue 1(2014)
- Journal:
- Transfusion medicine
- Issue:
- Volume 24:Issue 1(2014)
- Issue Display:
- Volume 24, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2014-0024-0001-0000
- Page Start:
- 33
- Page End:
- 38
- Publication Date:
- 2013-11-05
- Subjects:
- Blood -- Transfusion -- Periodicals
615.39 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=tme ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-3148 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/tme.12073 ↗
- Languages:
- English
- ISSNs:
- 0958-7578
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.706000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4329.xml