Vibrant Soundbridge implantation via the third window in two Chinese patients with severe bilateral congenital aural atresia. (January 2014)
- Record Type:
- Journal Article
- Title:
- Vibrant Soundbridge implantation via the third window in two Chinese patients with severe bilateral congenital aural atresia. (January 2014)
- Main Title:
- Vibrant Soundbridge implantation via the third window in two Chinese patients with severe bilateral congenital aural atresia
- Authors:
- Yang, Shi-Ming
Zou, Yi-Hui
Li, Jia-Nan
Jiao, Qing-Shan
Yi, Hai-Jin
Han, Dong-Yi - Abstract:
- <abstract> <title>Abstract</title> <p> <italic>Conclusion:</italic> In patients with undeveloped vestibular/oval windows and inaccessible round windows, Vibrant Soundbridge (VSB) implantation performed by placing the transducer into a reconstructed window on the inner tympanum wall demonstrated significant improvement in hearing and verbal communication ability. <italic>Objective:</italic> To report our surgical experience with new placement of the VSB in pediatric patients with undeveloped vestibular windows, inaccessible round windows, and severe bilateral congenital aural atresia (CAA). <italic>Methods:</italic> In two patients with bilateral CAA selected for middle ear implantation, CT scans revealed severe middle ear malformation including inaccessible round windows, absence of vestibular/oval windows, and abnormal facial nerve anatomy. The transducer of the VSB was implanted into a 'window' drilled at the inner tympanum wall in both patients. <italic>Results:</italic> The surgery was successful. Pure-tone air conduction thresholds across the frequencies of 0.25–8 Hz were improved by 35 dB (preoperation, 69.2 dB; postactivation, 34 dB) in patient 1 and 46.6 dB (preoperation, 75.8 dB; postactivation, 24.2 dB) in patient 2. Normal hearing thresholds were achieved in the range of 1–8 kHz in both patients. A sentence recognition rate of up to 100% (65 dB SPL in a quiet room) was attained by both patients after surgery and VSB activation at 3 months postoperatively.</p><abstract> <title>Abstract</title> <p> <italic>Conclusion:</italic> In patients with undeveloped vestibular/oval windows and inaccessible round windows, Vibrant Soundbridge (VSB) implantation performed by placing the transducer into a reconstructed window on the inner tympanum wall demonstrated significant improvement in hearing and verbal communication ability. <italic>Objective:</italic> To report our surgical experience with new placement of the VSB in pediatric patients with undeveloped vestibular windows, inaccessible round windows, and severe bilateral congenital aural atresia (CAA). <italic>Methods:</italic> In two patients with bilateral CAA selected for middle ear implantation, CT scans revealed severe middle ear malformation including inaccessible round windows, absence of vestibular/oval windows, and abnormal facial nerve anatomy. The transducer of the VSB was implanted into a 'window' drilled at the inner tympanum wall in both patients. <italic>Results:</italic> The surgery was successful. Pure-tone air conduction thresholds across the frequencies of 0.25–8 Hz were improved by 35 dB (preoperation, 69.2 dB; postactivation, 34 dB) in patient 1 and 46.6 dB (preoperation, 75.8 dB; postactivation, 24.2 dB) in patient 2. Normal hearing thresholds were achieved in the range of 1–8 kHz in both patients. A sentence recognition rate of up to 100% (65 dB SPL in a quiet room) was attained by both patients after surgery and VSB activation at 3 months postoperatively.</p> </abstract> … (more)
- Is Part Of:
- Acta oto-laryngologica. Volume 134:Number 1(2014)
- Journal:
- Acta oto-laryngologica
- Issue:
- Volume 134:Number 1(2014)
- Issue Display:
- Volume 134, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 134
- Issue:
- 1
- Issue Sort Value:
- 2014-0134-0001-0000
- Page Start:
- 1
- Page End:
- 6
- Publication Date:
- 2014-01
- Subjects:
- Otolaryngology -- Periodicals
Ear -- Diseases -- Periodicals
Throat -- Diseases -- Periodicals
Otolaryngology -- Electronic Resources
Otorhinolaryngologic Diseases
617.8 - Journal URLs:
- http://www.tandfonline.com/loi/ioto20#.V6CqjFJTHcs ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/00016489.2013.840922 ↗
- Languages:
- English
- ISSNs:
- 0001-6489
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0642.250000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3061.xml