Bending moments of zirconia and titanium implant abutments supporting all‐ceramic crowns after aging. Issue 1 (4th June 2013)
- Record Type:
- Journal Article
- Title:
- Bending moments of zirconia and titanium implant abutments supporting all‐ceramic crowns after aging. Issue 1 (4th June 2013)
- Main Title:
- Bending moments of zirconia and titanium implant abutments supporting all‐ceramic crowns after aging
- Authors:
- Mühlemann, Sven
Truninger, Thomas C.
Stawarczyk, Bogna
Hämmerle, Christoph H. F.
Sailer, Irena - Abstract:
- <abstract abstract-type="main" id="clr12192-abs-0001"> <title>Abstract</title> <sec id="clr12192-sec-0001" sec-type="section"> <title>Objectives</title> <p>To test the fracture load and fracture patterns of zirconia abutments restored with all‐ceramic crowns after fatigue loading, exhibiting internal and external implant–abutment connections as compared to restored and internally fixed titanium abutments.</p> </sec> <sec id="clr12192-sec-0002" sec-type="section"> <title>Materials and methods</title> <p>A master abutment was used for the customization of 5 groups of zirconia abutments to a similar shape (test). The groups differed according to their implant–abutment connections: one‐piece internal connection (BL; Straumann Bonelevel), two‐piece internal connection (RS; Nobel Biocare ReplaceSelect), external connection (B; Branemark MkIII), two‐piece internal connection (SP, Straumann StandardPlus) and one‐piece internal connection (A; Astra Tech AB OsseoSpeed). Titanium abutments with internal implant–abutment connection (T; Straumann Bonelevel) served as control group. In each group, 12 abutments were fabricated, mounted to the respective implants and restored with glass–ceramic crowns. All samples were embedded in acrylic holders (ISO‐Norm 14801). After aging by means of thermocycling in a chewing simulator, static load was applied until failure (ISO‐Norm 14801). Fracture load was analyzed by calculating the bending moments. Values of all groups were compared with one‐way<abstract abstract-type="main" id="clr12192-abs-0001"> <title>Abstract</title> <sec id="clr12192-sec-0001" sec-type="section"> <title>Objectives</title> <p>To test the fracture load and fracture patterns of zirconia abutments restored with all‐ceramic crowns after fatigue loading, exhibiting internal and external implant–abutment connections as compared to restored and internally fixed titanium abutments.</p> </sec> <sec id="clr12192-sec-0002" sec-type="section"> <title>Materials and methods</title> <p>A master abutment was used for the customization of 5 groups of zirconia abutments to a similar shape (test). The groups differed according to their implant–abutment connections: one‐piece internal connection (BL; Straumann Bonelevel), two‐piece internal connection (RS; Nobel Biocare ReplaceSelect), external connection (B; Branemark MkIII), two‐piece internal connection (SP, Straumann StandardPlus) and one‐piece internal connection (A; Astra Tech AB OsseoSpeed). Titanium abutments with internal implant–abutment connection (T; Straumann Bonelevel) served as control group. In each group, 12 abutments were fabricated, mounted to the respective implants and restored with glass–ceramic crowns. All samples were embedded in acrylic holders (ISO‐Norm 14801). After aging by means of thermocycling in a chewing simulator, static load was applied until failure (ISO‐Norm 14801). Fracture load was analyzed by calculating the bending moments. Values of all groups were compared with one‐way ANOVA followed by Scheffé post hoc test (<italic>P</italic>‐value&lt;0.05). Failure mode was analyzed descriptively.</p> </sec> <sec id="clr12192-sec-0003" sec-type="section"> <title>Results</title> <p>The mean bending moments were 464.9 ± 106.6 N cm (BL), 581.8 ± 172.8 N cm (RS), 556.7 ± 128.4 N cm (B), 605.4 ± 54.7 N cm (SP), 216.4 ± 90.0 N cm (A) and 1042.0 ± 86.8 N cm (T). No difference of mean bending moments was found between groups BL, RS, B and SP. Test group A exhibited significantly lower mean bending moment than the other test groups. Control group T had significantly higher bending moments than all test groups. Failure due to fracture of the abutment and/or crown occurred in the test groups. In groups BL and A, fractures were located in the internal part of the connection, whereas in groups RS and SP, a partial deformation of the implant components occurred and cracks and fractures of the zirconia abutment were detected.</p> </sec> <sec id="clr12192-sec-0004" sec-type="section"> <title>Conclusion</title> <p>The differently connected zirconia abutments exhibited similar bending moments with the exception of one group. Hence, the type of connection only had a minor effect on the stability of restored zirconia abutments. In general, restored titanium abutments exhibited the highest bending moments.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical oral implants research. Volume 25:Issue 1(2014:Jan.)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 25:Issue 1(2014:Jan.)
- Issue Display:
- Volume 25, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 25
- Issue:
- 1
- Issue Sort Value:
- 2014-0025-0001-0000
- Page Start:
- 74
- Page End:
- 81
- Publication Date:
- 2013-06-04
- Subjects:
- Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.12192 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3588.xml