Biphasic intra-thoracic pressure regulation augments cardiac index during porcine peritonitis: a feasibility study. (January 2014)
- Record Type:
- Journal Article
- Title:
- Biphasic intra-thoracic pressure regulation augments cardiac index during porcine peritonitis: a feasibility study. (January 2014)
- Main Title:
- Biphasic intra-thoracic pressure regulation augments cardiac index during porcine peritonitis: a feasibility study
- Authors:
- Cinel, Ismail
Goldfarb, Roy D.
Metzger, Anja
Lurie, Keith
Jasti, Purnachandra
Knob, Christopher R.
Parrillo, Joseph E.
Phillip Dellinger, R. - Abstract:
- <abstract> <title>Abstract</title> <p>Preservation of cardiac output (CO) and pulmonary artery pressure (PAP) is vital to maintaining tissue oxygenation in sepsis. This feasibility study tested the hypothesis that therapeutic intra-thoracic pressure regulation (tIPR), delivered with a novel device, was designed to non-invasively enhance venous return by creating sub-atmospheric intra-thoracic pressure during the expiratory phase of mechanical ventilation, improves CO without fluid resuscitation in a porcine <italic>E. coli</italic> peritonitis model of sepsis. Seven pigs were intubated, anaesthetized and instrumented with a Swan-Ganz and femoral artery catheter. After a 30 min basal period, a fibrin clot containing 4–5 × 10<sup>9</sup> cfu kg<sup>−1</sup><italic>E. coli</italic> O111.B4 was implanted in the peritoneum. One hour after clot implantation, tIPR was utilized for 30 min and then removed from the ventilator circuit for 30 min. This tIPR cycle was repeated 4-times. Changes in haemodynamic parameters were calculated by comparing pre-tIPR values to peak values during tIPR administration. Following peritonitis, tIPR significantly increased the peak cardiac index (mean ± SEM) (14.8 ± 2.6 vs 7.9 ± 2.3 ml kg<sup>−1</sup>) and mean arterial pressure (10.2 ± 1.5 vs 4.9 ± 1.1 mmHg) and simultaneously decreased PAP (−7.7 ± 1.5 vs −2.7 ± 0.8 mmHg). These results support the feasibility of the concept that therapeutic application of negative expiratory pressure may provide a<abstract> <title>Abstract</title> <p>Preservation of cardiac output (CO) and pulmonary artery pressure (PAP) is vital to maintaining tissue oxygenation in sepsis. This feasibility study tested the hypothesis that therapeutic intra-thoracic pressure regulation (tIPR), delivered with a novel device, was designed to non-invasively enhance venous return by creating sub-atmospheric intra-thoracic pressure during the expiratory phase of mechanical ventilation, improves CO without fluid resuscitation in a porcine <italic>E. coli</italic> peritonitis model of sepsis. Seven pigs were intubated, anaesthetized and instrumented with a Swan-Ganz and femoral artery catheter. After a 30 min basal period, a fibrin clot containing 4–5 × 10<sup>9</sup> cfu kg<sup>−1</sup><italic>E. coli</italic> O111.B4 was implanted in the peritoneum. One hour after clot implantation, tIPR was utilized for 30 min and then removed from the ventilator circuit for 30 min. This tIPR cycle was repeated 4-times. Changes in haemodynamic parameters were calculated by comparing pre-tIPR values to peak values during tIPR administration. Following peritonitis, tIPR significantly increased the peak cardiac index (mean ± SEM) (14.8 ± 2.6 vs 7.9 ± 2.3 ml kg<sup>−1</sup>) and mean arterial pressure (10.2 ± 1.5 vs 4.9 ± 1.1 mmHg) and simultaneously decreased PAP (−7.7 ± 1.5 vs −2.7 ± 0.8 mmHg). These results support the feasibility of the concept that therapeutic application of negative expiratory pressure may provide a non-invasive and complementary approach to increase cardiac output and organ perfusion in the setting of septic shock.</p> </abstract> … (more)
- Is Part Of:
- Journal of medical engineering & technology. Volume 38:Number 1(2014)
- Journal:
- Journal of medical engineering & technology
- Issue:
- Volume 38:Number 1(2014)
- Issue Display:
- Volume 38, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2014-0038-0001-0000
- Page Start:
- 49
- Page End:
- 54
- Publication Date:
- 2014-01
- Subjects:
- Biomedical engineering -- Periodicals
Medical technology -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/journal/jmt ↗
http://www.tandfonline.com/toc/ijmt20/current ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/03091902.asp ↗ - DOI:
- 10.3109/03091902.2013.857733 ↗
- Languages:
- English
- ISSNs:
- 0309-1902
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.057000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3485.xml