Tissue‐ and column‐specific measurements from multi‐parameter mapping of the human cervical spinal cord at 3 T. (16th September 2013)
- Record Type:
- Journal Article
- Title:
- Tissue‐ and column‐specific measurements from multi‐parameter mapping of the human cervical spinal cord at 3 T. (16th September 2013)
- Main Title:
- Tissue‐ and column‐specific measurements from multi‐parameter mapping of the human cervical spinal cord at 3 T
- Authors:
- Samson, R. S.
Ciccarelli, O.
Kachramanoglou, C.
Brightman, L.
Lutti, A.
Thomas, D. L.
Weiskopf, N.
Wheeler‐Kingshott, C. A. M. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>The aim of this study was to quantify a range of MR parameters [apparent proton density, longitudinal relaxation time <italic>T</italic><sub>1</sub>, magnetisation transfer (MT) ratio, MT saturation (which represents the additional percentage MT saturation of the longitudinal magnetisation caused by a single MT pulse) and apparent transverse relaxation rate <italic>R</italic><sub>2</sub>*] in the white matter columns and grey matter of the healthy cervical spinal cord. The cervical cords of 13 healthy volunteers were scanned at 3 T using a protocol optimised for multi‐parameter mapping. Intra‐subject co‐registration was performed using linear registration, and tissue‐ and column‐specific parameter values were calculated. Cervical cord parameter values measured from levels C1–C5 in 13 subjects are: apparent proton density, 4822 ± 718 a.u.; MT ratio, 40.4 ± 1.53 p.u.; MT saturation, 1.40 ± 0.12 p.u.; <italic>T</italic><sub>1</sub> = 1848 ± 143 ms; <italic>R</italic><sub>2</sub>* = 22.6 ± 1.53 s<sup>–1</sup>. Inter‐subject coefficients of variation were low in both the cervical cord and tissue‐ and column‐specific measurements, illustrating the potential of this method for the investigation of changes in these parameters caused by pathology. In summary, an optimised cervical cord multi‐parameter mapping protocol was developed, enabling tissue‐ and column‐specific measurements to be made.<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>The aim of this study was to quantify a range of MR parameters [apparent proton density, longitudinal relaxation time <italic>T</italic><sub>1</sub>, magnetisation transfer (MT) ratio, MT saturation (which represents the additional percentage MT saturation of the longitudinal magnetisation caused by a single MT pulse) and apparent transverse relaxation rate <italic>R</italic><sub>2</sub>*] in the white matter columns and grey matter of the healthy cervical spinal cord. The cervical cords of 13 healthy volunteers were scanned at 3 T using a protocol optimised for multi‐parameter mapping. Intra‐subject co‐registration was performed using linear registration, and tissue‐ and column‐specific parameter values were calculated. Cervical cord parameter values measured from levels C1–C5 in 13 subjects are: apparent proton density, 4822 ± 718 a.u.; MT ratio, 40.4 ± 1.53 p.u.; MT saturation, 1.40 ± 0.12 p.u.; <italic>T</italic><sub>1</sub> = 1848 ± 143 ms; <italic>R</italic><sub>2</sub>* = 22.6 ± 1.53 s<sup>–1</sup>. Inter‐subject coefficients of variation were low in both the cervical cord and tissue‐ and column‐specific measurements, illustrating the potential of this method for the investigation of changes in these parameters caused by pathology. In summary, an optimised cervical cord multi‐parameter mapping protocol was developed, enabling tissue‐ and column‐specific measurements to be made. This technique has the potential to provide insight into the pathological processes occurring in the cervical cord affected by neurological disorders. © 2013 The Authors. <italic>NMR in Biomedicine</italic> published by John Wiley &amp; Sons, Ltd.</p> </abstract> … (more)
- Is Part Of:
- NMR in biomedicine. Volume 26:Number 12(2013:Dec.)
- Journal:
- NMR in biomedicine
- Issue:
- Volume 26:Number 12(2013:Dec.)
- Issue Display:
- Volume 26, Issue 12 (2013)
- Year:
- 2013
- Volume:
- 26
- Issue:
- 12
- Issue Sort Value:
- 2013-0026-0012-0000
- Page Start:
- 1823
- Page End:
- 1830
- Publication Date:
- 2013-09-16
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
574 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/nbm.3022 ↗
- Languages:
- English
- ISSNs:
- 0952-3480
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6113.931000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3435.xml