Extreme X‐ray beam compression for a high‐resolution table‐top grazing‐incidence small‐angle X‐ray scattering setup. (25th October 2013)
- Record Type:
- Journal Article
- Title:
- Extreme X‐ray beam compression for a high‐resolution table‐top grazing‐incidence small‐angle X‐ray scattering setup. (25th October 2013)
- Main Title:
- Extreme X‐ray beam compression for a high‐resolution table‐top grazing‐incidence small‐angle X‐ray scattering setup
- Authors:
- Jergel, Matej
Šiffalovič, Peter
Végsö, Karol
Majková, Eva
Korytár, Dušan
Zápražný, Zdenko
Perlich, Jan
Ziberi, Bashkim
Cornejo, Marina
Vagovic, Patrik - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title> <x xml:space="preserve">Abstract</x> </title> <p>The application of V‐shaped channel‐cut GeSi(220) and Ge(220) monochromators for one‐dimensional extreme X‐ray beam compression was tested on a table‐top setup for grazing‐incidence small‐angle X‐ray scattering (GISAXS) with a microfocus source. A lattice constant gradient and different asymmetry angles of the diffractors were employed to enhance the compression factor to 21 and 15, respectively. It was demonstrated that the output beam parameters in terms of the size, divergence, photon flux and spectral bandwidth surpass those of the slit collimators used traditionally in GISAXS. A beam size far below 100 µm allows a high‐resolution spatial GISAXS mapping, while the reciprocal space resolution of ∼500 nm approaches the level of synchrotron measurements and allows a fast one‐shot detection of high‐resolution GISAXS patterns. An oversampling shifts the detection limit up to ∼1 µm. The very short design of the compact high‐resolution table‐top GISAXS setup is another advantage of the extreme beam compression. Benefits of V‐shaped monochromators for medium‐resolution X‐ray diffraction experiments as a bonus application are demonstrated by a comparison with parallel channel‐cut monochromators combined with a slit.</p> </abstract>
- Is Part Of:
- Journal of applied crystallography. Volume 46:Part 6(2013:Dec.)
- Journal:
- Journal of applied crystallography
- Issue:
- Volume 46:Part 6(2013:Dec.)
- Issue Display:
- Volume 46, Issue 6, Part 6 (2013)
- Year:
- 2013
- Volume:
- 46
- Issue:
- 6
- Part:
- 6
- Issue Sort Value:
- 2013-0046-0006-0006
- Page Start:
- 1544
- Page End:
- 1550
- Publication Date:
- 2013-10-25
- Subjects:
- Crystallography -- Periodicals
548.05 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.iucr.org/j/journalhomepage.html ↗
http://www-us.ebsco.com/online/direct.asp?JournalID=105188 ↗
http://www.blackwell-synergy.com/loi/jcr ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=jcr&open=2004#C2004 ↗
http://onlinelibrary.wiley.com/journal/10.1107/S16005767 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1107/S0021889813024138 ↗
- Languages:
- English
- ISSNs:
- 0021-8898
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4942.400000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3036.xml