Parallel comparison of apheresis‐collected platelet concentrates stored in four different additive solutions. Issue 4 (27th June 2013)
- Record Type:
- Journal Article
- Title:
- Parallel comparison of apheresis‐collected platelet concentrates stored in four different additive solutions. Issue 4 (27th June 2013)
- Main Title:
- Parallel comparison of apheresis‐collected platelet concentrates stored in four different additive solutions
- Authors:
- Nogawa, M.
Naito, Y.
Chatani, M.
Onodera, H.
Shiba, M.
Okazaki, H.
Matsuzaki, K.
Satake, M.
Nakajima, K.
Tadokoro, K. - Abstract:
- <abstract abstract-type="main" id="vox12064-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="vox12064-sec-0001" sec-type="section"> <title>Background and Objectives</title> <p>Partially replacing plasma with additive solutions in platelet (PLT) concentrates (PCs) may help to reduce transfusion reactions. Constituents of PLT additive solutions (PASs) have been revealed to affect the quality of PCs. Previous studies involved pairwise comparison of identical PLTs with two different PASs or multicomparison using random PLTs with three or more PASs. In this study, we performed parallel comparison using PCs from identical donors with four PASs. In addition to traditional parameters, the release of bioactive substances and plasma proteins was assessed.</p> </sec> <sec id="vox12064-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Platelets collected four times by apheresis from three donors were suspended in Intersol, SSP+, Composol or M‐sol with 35% autologous plasma. The PC parameters, including PLT activation markers, glucose consumption, chemokines and plasma proteins, were assessed during 5‐day storage.</p> </sec> <sec id="vox12064-sec-0003" sec-type="section"> <title>Results</title> <p>Mean PLT volumes were decreased in SSP+, Composol and M‐sol after 5‐day storage, with significant differences, whereas the hypertonic shock response (HSR) was decreased only in Intersol. Glucose consumption was faster in Intersol and M‐sol than in<abstract abstract-type="main" id="vox12064-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="vox12064-sec-0001" sec-type="section"> <title>Background and Objectives</title> <p>Partially replacing plasma with additive solutions in platelet (PLT) concentrates (PCs) may help to reduce transfusion reactions. Constituents of PLT additive solutions (PASs) have been revealed to affect the quality of PCs. Previous studies involved pairwise comparison of identical PLTs with two different PASs or multicomparison using random PLTs with three or more PASs. In this study, we performed parallel comparison using PCs from identical donors with four PASs. In addition to traditional parameters, the release of bioactive substances and plasma proteins was assessed.</p> </sec> <sec id="vox12064-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Platelets collected four times by apheresis from three donors were suspended in Intersol, SSP+, Composol or M‐sol with 35% autologous plasma. The PC parameters, including PLT activation markers, glucose consumption, chemokines and plasma proteins, were assessed during 5‐day storage.</p> </sec> <sec id="vox12064-sec-0003" sec-type="section"> <title>Results</title> <p>Mean PLT volumes were decreased in SSP+, Composol and M‐sol after 5‐day storage, with significant differences, whereas the hypertonic shock response (HSR) was decreased only in Intersol. Glucose consumption was faster in Intersol and M‐sol than in SSP+ or Composol. PLT activation, determined as CD62P, sCD62P, sCD40L and RANTES, was significantly higher in Intersol than the other three PASs. No marked change was observed in fibrinopeptide A and C3a in any PASs.</p> </sec> <sec id="vox12064-sec-0004" sec-type="section"> <title>Conclusions</title> <p>M‐sol, SSP+ and Composol effectively preserved the quality of PCs. PLT activation was significantly enhanced in Intersol compared with the other three PASs. These effects seem to depend on magnesium and potassium as a constituent. Parallel comparison further verified that the PC quality largely depended on PASs but not donors.</p> </sec> </abstract> … (more)
- Is Part Of:
- Vox sanguinis. Volume 105:Issue 4(2013)
- Journal:
- Vox sanguinis
- Issue:
- Volume 105:Issue 4(2013)
- Issue Display:
- Volume 105, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 105
- Issue:
- 4
- Issue Sort Value:
- 2013-0105-0004-0000
- Page Start:
- 305
- Page End:
- 312
- Publication Date:
- 2013-06-27
- Subjects:
- Blood -- Periodicals
Blood -- Transfusion -- Periodicals
Immunohematology -- Periodicals
Immunopathology -- Periodicals
615.39 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1423-0410 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=vox ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/vox.12064 ↗
- Languages:
- English
- ISSNs:
- 0042-9007
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9258.700000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3327.xml