Automatic delineation for replanning in nasopharynx radiotherapy: What is the agreement among experts to be considered as benchmark?. (October 2013)
- Record Type:
- Journal Article
- Title:
- Automatic delineation for replanning in nasopharynx radiotherapy: What is the agreement among experts to be considered as benchmark?. (October 2013)
- Main Title:
- Automatic delineation for replanning in nasopharynx radiotherapy: What is the agreement among experts to be considered as benchmark?
- Authors:
- Mattiucci, Gian Carlo
Boldrini, Luca
Chiloiro, Giuditta
D'Agostino, Giuseppe Roberto
Chiesa, Silvia
De Rose, Fiorenza
Azario, Luigi
Pasini, Danilo
Gambacorta, Maria Antonietta
Balducci, Mario
Valentini, Vincenzo - Abstract:
- <abstract> <title>Abstract</title> <p> <italic>Background and purpose.</italic> Anatomic changes during head and neck radiotherapy require replanning. The primary aim of this study is the definition of the agreement among experts in the head and neck automatic delineation frame to use as benchmark. The secondary goal is to assess the reliability of automatic delineation for nasopharynx radiotherapy and time saving. <italic>Material and methods.</italic> A computed tomography (CT) scan was acquired in 10 nasopharynx patients along intensity-modulated radiotherapy (IMRT) treatment for replanning. Deformable registration with replanning autocontouring of the structures was performed using VelocityAI 2.3© software defining Structure Set A. The optimization of these contours was obtained through revision by a skilled operator, drawing Structure Set B. An ex novo Structure Set C was segmented on the replanning CT-scan by an expert delineation team. The mean Dice's Similarity Index (mDSI) was calculated between Structure Set A and B, A and C, and between B and C for each volume. All segmentation times for organs at risk (OARs) and clinical target volume (CTV) were recorded and compared. <italic>Results.</italic> We validated the replanning autocontoured Structure Sets for 10 patients. For volumetric analysis we observed mDSI values of 0.87 for the OARs, 0.70 for nodes, 0.90 for CTV in the Structure Set A-B comparison and respectively of 0.74, 0.63 and 0.78 for the Structure Set A-C<abstract> <title>Abstract</title> <p> <italic>Background and purpose.</italic> Anatomic changes during head and neck radiotherapy require replanning. The primary aim of this study is the definition of the agreement among experts in the head and neck automatic delineation frame to use as benchmark. The secondary goal is to assess the reliability of automatic delineation for nasopharynx radiotherapy and time saving. <italic>Material and methods.</italic> A computed tomography (CT) scan was acquired in 10 nasopharynx patients along intensity-modulated radiotherapy (IMRT) treatment for replanning. Deformable registration with replanning autocontouring of the structures was performed using VelocityAI 2.3© software defining Structure Set A. The optimization of these contours was obtained through revision by a skilled operator, drawing Structure Set B. An ex novo Structure Set C was segmented on the replanning CT-scan by an expert delineation team. The mean Dice's Similarity Index (mDSI) was calculated between Structure Set A and B, A and C, and between B and C for each volume. All segmentation times for organs at risk (OARs) and clinical target volume (CTV) were recorded and compared. <italic>Results.</italic> We validated the replanning autocontoured Structure Sets for 10 patients. For volumetric analysis we observed mDSI values of 0.87 for the OARs, 0.70 for nodes, 0.90 for CTV in the Structure Set A-B comparison and respectively of 0.74, 0.63 and 0.78 for the Structure Set A-C one, and 0.78, 0.78 and 0.85 for Structure Set B-C, which represents the existing expert based benchmark. We calculated a mean saved time in Structure Set B of 30 minutes. <italic>Conclusions.</italic> Autocontouring procedures offer considerable segmentation time saving with acceptable reliability of the contours, even if an independent check procedure for their optimization is still required to increase their adherence to referential benchmark gold standard among experts, which stands at a 0.80 DSI value.</p> </abstract> … (more)
- Is Part Of:
- Acta oncologica. Volume 52:Number 7(2013)
- Journal:
- Acta oncologica
- Issue:
- Volume 52:Number 7(2013)
- Issue Display:
- Volume 52, Issue 7 (2013)
- Year:
- 2013
- Volume:
- 52
- Issue:
- 7
- Issue Sort Value:
- 2013-0052-0007-0000
- Page Start:
- 1417
- Page End:
- 1422
- Publication Date:
- 2013-10
- Subjects:
- Oncology -- Periodicals
Cancer -- Treatment -- Periodicals
616.992 - Journal URLs:
- http://informahealthcare.com/loi/onc ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/0284186X.2013.813069 ↗
- Languages:
- English
- ISSNs:
- 0284-186X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.705000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3729.xml