A rapid analytical method for the quantification of paclitaxel in rat plasma and brain tissue by high‐performance liquid chromatography and tandem mass spectrometry. (2nd September 2013)
- Record Type:
- Journal Article
- Title:
- A rapid analytical method for the quantification of paclitaxel in rat plasma and brain tissue by high‐performance liquid chromatography and tandem mass spectrometry. (2nd September 2013)
- Main Title:
- A rapid analytical method for the quantification of paclitaxel in rat plasma and brain tissue by high‐performance liquid chromatography and tandem mass spectrometry
- Authors:
- Li, Pei
Albrecht, Benjamin J.
Yan, Xisheng
Gao, Mei
Weng, Han‐Rong
Bartlett, Michael G. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="rcm6671-sec-0001" sec-type="section"> <title>RATIONALE</title> <p>Paclitaxel, an antitumor agent for the treatment of several types of cancers, has recently been reported to cause impaired cognitive function and neuropathic pain in humans. To assess the effects of paclitaxel on the central nervous system, a sensitive and accurate method is required to quantify paclitaxel concentrations in plasma and brain tissue obtained from rodents receiving paclitaxel.</p> </sec> <sec id="rcm6671-sec-0002" sec-type="section"> <title>METHODS</title> <p>The biological samples were prepared by liquid‐liquid extraction and separated by a 3.5 min reversed‐phase liquid chromatography (RPLC) method using a BDS Hypersil C8 column under isocratic conditions. Paclitaxel was quantified using multiple reaction monitoring (MRM) with a triple quadrupole tandem mass spectrometer working in the positive electrospray ionization (ESI+) mode. A stable isotope labeled analogue of paclitaxel was used as the internal standard (IS).</p> </sec> <sec id="rcm6671-sec-0003" sec-type="section"> <title>RESULTS</title> <p>The method was validated to be precise and accurate within the dynamic range of 0.5‐100 ng/mL based on 100 μL plasma and 1.5–300 ng/g based on 33 mg of brain tissue in homogenate. This method was applied to samples from 2 mg/kg intravenously dosed rats. The plasma concentrations were observed to be<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="rcm6671-sec-0001" sec-type="section"> <title>RATIONALE</title> <p>Paclitaxel, an antitumor agent for the treatment of several types of cancers, has recently been reported to cause impaired cognitive function and neuropathic pain in humans. To assess the effects of paclitaxel on the central nervous system, a sensitive and accurate method is required to quantify paclitaxel concentrations in plasma and brain tissue obtained from rodents receiving paclitaxel.</p> </sec> <sec id="rcm6671-sec-0002" sec-type="section"> <title>METHODS</title> <p>The biological samples were prepared by liquid‐liquid extraction and separated by a 3.5 min reversed‐phase liquid chromatography (RPLC) method using a BDS Hypersil C8 column under isocratic conditions. Paclitaxel was quantified using multiple reaction monitoring (MRM) with a triple quadrupole tandem mass spectrometer working in the positive electrospray ionization (ESI+) mode. A stable isotope labeled analogue of paclitaxel was used as the internal standard (IS).</p> </sec> <sec id="rcm6671-sec-0003" sec-type="section"> <title>RESULTS</title> <p>The method was validated to be precise and accurate within the dynamic range of 0.5‐100 ng/mL based on 100 μL plasma and 1.5–300 ng/g based on 33 mg of brain tissue in homogenate. This method was applied to samples from 2 mg/kg intravenously dosed rats. The plasma concentrations were observed to be 26.62 ± 8.93 ng/mL and brain concentrations 11.08 ± 4.18 ng/g when measured 4 h post‐dose.</p> </sec> <sec id="rcm6671-sec-0004" sec-type="section"> <title>CONCLUSIONS</title> <p>This rapid LC/MS/MS method was validated to be sensitive, specific, precise and accurate for the quantification of paclitaxel in rat plasma and brain tissue homogenate. Application of the method to study samples provided sufficient proof of blood–brain barrier penetration of paclitaxel, allowing further investigation of its influence on the central nervous system. Copyright © 2013 John Wiley &amp; Sons, Ltd.</p> </sec> </abstract> … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 27:Number 19(2013)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 27:Number 19(2013)
- Issue Display:
- Volume 27, Issue 19 (2013)
- Year:
- 2013
- Volume:
- 27
- Issue:
- 19
- Issue Sort Value:
- 2013-0027-0019-0000
- Page Start:
- 2127
- Page End:
- 2134
- Publication Date:
- 2013-09-02
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.6671 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3064.xml