Intensive training program for ultrasound diagnosis of adnexal masses: protocol and preliminary results. (9th July 2013)
- Record Type:
- Journal Article
- Title:
- Intensive training program for ultrasound diagnosis of adnexal masses: protocol and preliminary results. (9th July 2013)
- Main Title:
- Intensive training program for ultrasound diagnosis of adnexal masses: protocol and preliminary results
- Authors:
- Alcázar, J. L.
Díaz, L.
Flórez, P.
Guerriero, S.
Jurado, M. - Abstract:
- <abstract abstract-type="main" id="uog12440-abs-0001"> <title>ABSTRACT</title> <sec id="uog12440-sec-0001" sec-type="section"> <title>Objective</title> <p id="uog12440-para-0001">To assess the feasibility of a specific training program for ultrasound diagnosis of adnexal masses.</p> </sec> <sec id="uog12440-sec-0002" sec-type="section"> <title>Methods</title> <p id="uog12440-para-0002">A 2‐month intensive training program was developed. The program protocol consisted of a 1‐day intensive theoretical course focused on clinical and sonographic issues related to adnexal masses and ovarian cancer, followed by a 4‐week real‐time ultrasound training program in a tertiary center (25–30 adnexal masses evaluated per month) and a final 4‐week period for offline assessment of three‐dimensional (3D) volumes from adnexal masses. In this final period, each trainee evaluated five sets of 100 3D volumes. 3D volumes contained gray‐scale and power Doppler information, and the trainee was provided with clinical data for each case (patient age, menopausal status and reported symptoms). 3D volumes were obtained from surgically removed masses that had undergone histological diagnosis or from masses that had been followed up until resolution. After assessment of each set, the trainee's diagnostic performance was calculated (sensitivity and specificity) and each incorrectly classified mass was evaluated with the trainer. The objective was to achieve a sensitivity of &gt; 95% and a specificity of<abstract abstract-type="main" id="uog12440-abs-0001"> <title>ABSTRACT</title> <sec id="uog12440-sec-0001" sec-type="section"> <title>Objective</title> <p id="uog12440-para-0001">To assess the feasibility of a specific training program for ultrasound diagnosis of adnexal masses.</p> </sec> <sec id="uog12440-sec-0002" sec-type="section"> <title>Methods</title> <p id="uog12440-para-0002">A 2‐month intensive training program was developed. The program protocol consisted of a 1‐day intensive theoretical course focused on clinical and sonographic issues related to adnexal masses and ovarian cancer, followed by a 4‐week real‐time ultrasound training program in a tertiary center (25–30 adnexal masses evaluated per month) and a final 4‐week period for offline assessment of three‐dimensional (3D) volumes from adnexal masses. In this final period, each trainee evaluated five sets of 100 3D volumes. 3D volumes contained gray‐scale and power Doppler information, and the trainee was provided with clinical data for each case (patient age, menopausal status and reported symptoms). 3D volumes were obtained from surgically removed masses that had undergone histological diagnosis or from masses that had been followed up until resolution. After assessment of each set, the trainee's diagnostic performance was calculated (sensitivity and specificity) and each incorrectly classified mass was evaluated with the trainer. The objective was to achieve a sensitivity of &gt; 95% and a specificity of &gt; 90%. Learning curve cumulative summation (LC‐CUSUM) graphs were plotted to assess the learning curve for the trainees.</p> </sec> <sec id="uog12440-sec-0003" sec-type="section"> <title>Results</title> <p id="uog12440-para-0003">One trainer and two trainees with little experience in gynecological ultrasound (one gynecologist and one radiologist) participated in this study. LC‐CUSUM graphs showed that competence was achieved after 170 or 185 examinations. The objectives for diagnostic performance were achieved after assessment of the second set of 3D volumes (200 cases) for each trainee.</p> </sec> <sec id="uog12440-sec-0004" sec-type="section"> <title>Conclusions</title> <p id="uog12440-para-0004">The proposed training program appears to be feasible. High diagnostic performance can be achieved after analysis of 200 cases and maintained thereafter. Copyright © 2013 ISUOG. Published by John Wiley &amp; Sons Ltd.</p> </sec> </abstract> … (more)
- Is Part Of:
- Ultrasound in obstetrics & gynecology. Volume 42:Number 2(2013:Aug.)
- Journal:
- Ultrasound in obstetrics & gynecology
- Issue:
- Volume 42:Number 2(2013:Aug.)
- Issue Display:
- Volume 42, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 42
- Issue:
- 2
- Issue Sort Value:
- 2013-0042-0002-0000
- Page Start:
- 218
- Page End:
- 223
- Publication Date:
- 2013-07-09
- Subjects:
- Ultrasonics in obstetrics -- Periodicals
Generative organs, Female -- Diseases -- Diagnosis -- Periodicals
Diagnosis, Ultrasonic -- Periodicals
Genital Diseases, Female -- ultrasonography -- Periodicals
Ultrasonography, Prenatal -- Periodicals
618.047543 - Journal URLs:
- http://obgyn.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1469-0705/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/uog.12440 ↗
- Languages:
- English
- ISSNs:
- 0960-7692
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9082.815300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3914.xml