Experimental investigation of the stent–artery interaction. (October 2013)
- Record Type:
- Journal Article
- Title:
- Experimental investigation of the stent–artery interaction. (October 2013)
- Main Title:
- Experimental investigation of the stent–artery interaction
- Authors:
- Zhao, Shijia
Gu, Linxia
Froemming, Stacey R. - Abstract:
- <abstract> <title>Abstract</title> <p>It is well acknowledged that stent implantation causes abnormal stretch and strains on the arterial wall, which contribute to the formation and progression of restenosis. However, the experimental characterization of the strain field on the stented vessel is scant. In this work, the balloon-expandable stent implantation inside an artery analogue was captured through two high-speed CCD cameras. The surface strain maps on the stented tube were quantified with a 3-D digital image correlation technique. The strain history at one specific reference point illustrated three stenting phases, including balloon inflation, pressurization and deflation. The surface strain distributions along one axial path were obtained at various time points to demonstrate the stent–vessel interactions. The radial wall thickness reduction history was used to evaluate the pressure–diameter relationship for the balloon. Results indicated that the expansion process of the balloon was significantly altered by the external loadings from both the stent and artery analogue. In addition, the repeatability of the stenting experiments was demonstrated through two tests with a change of 5% in the stent-induced maximum first principal strain. Moreover, a computational model of the stenting procedure was developed to recapture the stenting experiments. Comparison between experiments and simulation showed a difference of 7.17% in the first principal strain averaged over the high<abstract> <title>Abstract</title> <p>It is well acknowledged that stent implantation causes abnormal stretch and strains on the arterial wall, which contribute to the formation and progression of restenosis. However, the experimental characterization of the strain field on the stented vessel is scant. In this work, the balloon-expandable stent implantation inside an artery analogue was captured through two high-speed CCD cameras. The surface strain maps on the stented tube were quantified with a 3-D digital image correlation technique. The strain history at one specific reference point illustrated three stenting phases, including balloon inflation, pressurization and deflation. The surface strain distributions along one axial path were obtained at various time points to demonstrate the stent–vessel interactions. The radial wall thickness reduction history was used to evaluate the pressure–diameter relationship for the balloon. Results indicated that the expansion process of the balloon was significantly altered by the external loadings from both the stent and artery analogue. In addition, the repeatability of the stenting experiments was demonstrated through two tests with a change of 5% in the stent-induced maximum first principal strain. Moreover, a computational model of the stenting procedure was developed to recapture the stenting experiments. Comparison between experiments and simulation showed a difference of 7.17% in the first principal strain averaged over the high strain area. This indicated the validation of the computational framework, which can be used to investigate the strain or stress field throughout the computational domain, a feature that is not affected by experimental techniques.</p> </abstract> … (more)
- Is Part Of:
- Journal of medical engineering & technology. Volume 37:Number 7(2013)
- Journal:
- Journal of medical engineering & technology
- Issue:
- Volume 37:Number 7(2013)
- Issue Display:
- Volume 37, Issue 7 (2013)
- Year:
- 2013
- Volume:
- 37
- Issue:
- 7
- Issue Sort Value:
- 2013-0037-0007-0000
- Page Start:
- 463
- Page End:
- 469
- Publication Date:
- 2013-10
- Subjects:
- Biomedical engineering -- Periodicals
Medical technology -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/journal/jmt ↗
http://www.tandfonline.com/toc/ijmt20/current ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/03091902.asp ↗ - DOI:
- 10.3109/03091902.2013.831491 ↗
- Languages:
- English
- ISSNs:
- 0309-1902
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.057000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3818.xml