Evaluation of a rapid lateral flow immunoassay for the detection of cryptococcal antigen for the early diagnosis of cryptococcosis in HIV patients in Colombia. (October 2013)
- Record Type:
- Journal Article
- Title:
- Evaluation of a rapid lateral flow immunoassay for the detection of cryptococcal antigen for the early diagnosis of cryptococcosis in HIV patients in Colombia. (October 2013)
- Main Title:
- Evaluation of a rapid lateral flow immunoassay for the detection of cryptococcal antigen for the early diagnosis of cryptococcosis in HIV patients in Colombia
- Authors:
- Escandón, Patricia
Lizarazo, Jairo
Agudelo, Clara Ines
Chiller, Tom
Castañeda, Elizabeth - Abstract:
- <abstract> <title>Abstract</title> <p>A previous study carried out in a tertiary care hospital in Colombia demonstrated the usefulness of the <italic>Cryptococcus</italic> capsular antigen detection by latex (CrAg Latex) in the early diagnosis of cryptococcosis in HIV-infected patients with low CD4 + levels. The aim of this study was to establish the performance of a new rapid lateral flow assay (CrAg LFA) in preserved sera of those HIV-infected patients collected between 2001 and 2006. A total of 421 sera from 297 patients with a confirmed diagnosis of HIV were tested with CrAg LFA and results compared with those obtained with CrAg Latex. All patients provided informed consent for specimen collection. A concordance of 100% was found between positive results obtained by both methods. However, 13 sera that were negative by CrAg Latex, were positive by CrAg LFA (3.1%). In these positive patients, median of CD4 + levels was 67 cells/μl (8–608 cells/μl), while median of viral load was 118, 965 copies/ml (50–500, 000 copies/ml). Patients who were negative for cryptococcosis had a median of 177 cells/μl in CD4 + levels (4–2516 cells/μl) and a median of 62, 318 copies/ml in viral loads (25–50, 000 copies/ml). A significant statistical difference was found when comparing CD4 + levels and viral load in patients positive for cryptococcosis and those that were proven to be negative (<italic>P</italic> &lt; 0.0001). The use of Point-of-Care Tests (POCT) like CrAg LFA play an important<abstract> <title>Abstract</title> <p>A previous study carried out in a tertiary care hospital in Colombia demonstrated the usefulness of the <italic>Cryptococcus</italic> capsular antigen detection by latex (CrAg Latex) in the early diagnosis of cryptococcosis in HIV-infected patients with low CD4 + levels. The aim of this study was to establish the performance of a new rapid lateral flow assay (CrAg LFA) in preserved sera of those HIV-infected patients collected between 2001 and 2006. A total of 421 sera from 297 patients with a confirmed diagnosis of HIV were tested with CrAg LFA and results compared with those obtained with CrAg Latex. All patients provided informed consent for specimen collection. A concordance of 100% was found between positive results obtained by both methods. However, 13 sera that were negative by CrAg Latex, were positive by CrAg LFA (3.1%). In these positive patients, median of CD4 + levels was 67 cells/μl (8–608 cells/μl), while median of viral load was 118, 965 copies/ml (50–500, 000 copies/ml). Patients who were negative for cryptococcosis had a median of 177 cells/μl in CD4 + levels (4–2516 cells/μl) and a median of 62, 318 copies/ml in viral loads (25–50, 000 copies/ml). A significant statistical difference was found when comparing CD4 + levels and viral load in patients positive for cryptococcosis and those that were proven to be negative (<italic>P</italic> &lt; 0.0001). The use of Point-of-Care Tests (POCT) like CrAg LFA play an important role in the diagnosis of infectious diseases, especially in resource limited settings, where it will be a useful means to diagnose cryptococcosis early in HIV patients.</p> </abstract> … (more)
- Is Part Of:
- Medical mycology. Volume 51:Number 7(2013)
- Journal:
- Medical mycology
- Issue:
- Volume 51:Number 7(2013)
- Issue Display:
- Volume 51, Issue 7 (2013)
- Year:
- 2013
- Volume:
- 51
- Issue:
- 7
- Issue Sort Value:
- 2013-0051-0007-0000
- Page Start:
- 765
- Page End:
- 768
- Publication Date:
- 2013-10
- Subjects:
- Medical mycology -- Periodicals
Veterinary mycology -- Periodicals
Mycology -- Periodicals
Mycoses -- Periodicals
Pathogenic fungi -- Periodicals
616.969005 - Journal URLs:
- http://mmy.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.3109/13693786.2013.781692 ↗
- Languages:
- English
- ISSNs:
- 1369-3786
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5530.168000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3263.xml