Implanted cardiac devices are reliably detected by commercially available metal detectors. (October 2013)
- Record Type:
- Journal Article
- Title:
- Implanted cardiac devices are reliably detected by commercially available metal detectors. (October 2013)
- Main Title:
- Implanted cardiac devices are reliably detected by commercially available metal detectors
- Authors:
- Holm, Katja F.
Hjortshøj, Søren
Pehrson, Steen
Svendsen, Jesper Hastrup
Riahi, Sam - Abstract:
- <abstract> <title>Abstract</title> <p> <italic>Objective.</italic> Explosions of Cardiovascular Implantable Electronic Devices (CIEDs) (pacemakers, defibrillators, and loop recorders) are a well-recognized problem during cremation, due to lithium–iodine batteries. In addition, burial of the deceased with a CIED can present a potential risk for environmental contamination. Therefore, detection of CIEDs in the deceased would be of value. This study evaluated a commercially available metal detector for detecting CIEDs. <italic>Design.</italic> Observational study including pacemaker patients (<italic>n</italic> = 70) and a control group without pacemaker (<italic>n</italic> = 95). The investigational device was a hand-held metal detector for detecting metal or electricity wiring. <italic>Results.</italic> The metal detector detected the pacemaker in all pacemaker patients and thus exhibited a sensitivity of 100%. The specificity of the metal detector was 86%, and the negative predictive value was 100%. Thirteen individuals without pacemakers were falsely identified as having an implanted device due to implanted prosthetic material or elements of clothing. <italic>Conclusion.</italic> A simple hand-held metal detector may detect CIEDs with a high sensitivity. It may be of value in detecting CIEDs in deceased persons before burial or cremation. Any signal detected by the metal detector should prompt further investigation of the body and patient files.</p> </abstract>
- Is Part Of:
- Scandinavian cardiovascular journal. Volume 47:Number 5(2013:Oct.)
- Journal:
- Scandinavian cardiovascular journal
- Issue:
- Volume 47:Number 5(2013:Oct.)
- Issue Display:
- Volume 47, Issue 5 (2013)
- Year:
- 2013
- Volume:
- 47
- Issue:
- 5
- Issue Sort Value:
- 2013-0047-0005-0000
- Page Start:
- 271
- Page End:
- 274
- Publication Date:
- 2013-10
- Subjects:
- Cardiovascular system -- Diseases -- Periodicals
617.41 - Journal URLs:
- http://informahealthcare.com/loi/cdv ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/14017431.2013.823516 ↗
- Languages:
- English
- ISSNs:
- 1401-7431
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.472600
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3838.xml