A multicentre, randomized clinical trial comparing the Veriset™ haemostatic patch with fibrin sealant for the management of bleeding during hepatic surgery. Issue 7 (27th December 2012)
- Record Type:
- Journal Article
- Title:
- A multicentre, randomized clinical trial comparing the Veriset™ haemostatic patch with fibrin sealant for the management of bleeding during hepatic surgery. Issue 7 (27th December 2012)
- Main Title:
- A multicentre, randomized clinical trial comparing the Veriset™ haemostatic patch with fibrin sealant for the management of bleeding during hepatic surgery
- Authors:
- Öllinger, Robert
Mihaljevic, Andre L.
Schuhmacher, Christoph
Bektas, Hüseyin
Vondran, Florian
Kleine, Moritz
Sainz‐Barriga, Mauricio
Weiss, Sascha
Knebel, Phillip
Pratschke, Johann
Troisi, Roberto I. - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="hpb12009-sec-0001" sec-type="section"> <title>Background</title> <p>Bleeding during hepatic surgery is associated with prolonged hospitalization and increased morbidity and mortality. The Veriset™ haemostatic patch is a topical haemostat comprised of an absorbable backing made of oxidized cellulose and self‐adhesive hydrogel components. It is designed to achieve haemostasis quickly and adhere to tissues without fixation.</p> </sec> <sec id="hpb12009-sec-0002" sec-type="section"> <title>Methods</title> <p>A prospective, randomized, multicentre, single‐blinded study (<italic>n</italic> = 50) was performed to compare the use of a Veriset™ haemostatic patch with a fibrin sealant patch (TachoSil<sup>®</sup>) (control) in the management of diffuse bleeding after hepatic surgery. Patients were randomized following the confirmation of diffuse bleeding requiring the use of a topical haemostat. Time to haemostasis was assessed at preset intervals until haemostasis was achieved.</p> </sec> <sec id="hpb12009-sec-0003" sec-type="section"> <title>Results</title> <p>Both groups were similar in comorbidities and procedural techniques. The median time to haemostasis in the group using the Veriset™ haemostatic patch was 1.0 min compared with 3.0 min in the control group (<italic>P</italic> &lt; 0.001; 3‐min minimum application time for the control patch). This result was independent of bleeding severity and surface area. Both<abstract abstract-type="main"> <title>Abstract</title> <sec id="hpb12009-sec-0001" sec-type="section"> <title>Background</title> <p>Bleeding during hepatic surgery is associated with prolonged hospitalization and increased morbidity and mortality. The Veriset™ haemostatic patch is a topical haemostat comprised of an absorbable backing made of oxidized cellulose and self‐adhesive hydrogel components. It is designed to achieve haemostasis quickly and adhere to tissues without fixation.</p> </sec> <sec id="hpb12009-sec-0002" sec-type="section"> <title>Methods</title> <p>A prospective, randomized, multicentre, single‐blinded study (<italic>n</italic> = 50) was performed to compare the use of a Veriset™ haemostatic patch with a fibrin sealant patch (TachoSil<sup>®</sup>) (control) in the management of diffuse bleeding after hepatic surgery. Patients were randomized following the confirmation of diffuse bleeding requiring the use of a topical haemostat. Time to haemostasis was assessed at preset intervals until haemostasis was achieved.</p> </sec> <sec id="hpb12009-sec-0003" sec-type="section"> <title>Results</title> <p>Both groups were similar in comorbidities and procedural techniques. The median time to haemostasis in the group using the Veriset™ haemostatic patch was 1.0 min compared with 3.0 min in the control group (<italic>P</italic> &lt; 0.001; 3‐min minimum application time for the control patch). This result was independent of bleeding severity and surface area. Both products had similar safety profiles and no statistical differences were observed in the occurrence of adverse or device‐related events.</p> </sec> <sec id="hpb12009-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Regardless of bleeding severity or surface area, the Veriset™ haemostatic patch achieved haemostasis in this setting significantly faster than the control device in patients undergoing hepatic resection. It was safe and easy to handle in open hepatic surgery.</p> </sec> </abstract> … (more)
- Is Part Of:
- HPB. Volume 15:Issue 7(2013:Jul.)
- Journal:
- HPB
- Issue:
- Volume 15:Issue 7(2013:Jul.)
- Issue Display:
- Volume 15, Issue 7 (2013)
- Year:
- 2013
- Volume:
- 15
- Issue:
- 7
- Issue Sort Value:
- 2013-0015-0007-0000
- Page Start:
- 548
- Page End:
- 558
- Publication Date:
- 2012-12-27
- Subjects:
- Liver -- Diseases -- Periodicals
Biliary tract -- Diseases -- Periodicals
Pancreas -- Diseases -- Periodicals
616.362005 - Journal URLs:
- https://www.journals.elsevier.com/hpb/ ↗
http://www.hpbonline.org/current ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1477-2574 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/hpb.12009 ↗
- Languages:
- English
- ISSNs:
- 1365-182X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4335.262340
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4364.xml