Validation of the femoral component placement during hip resurfacing: a comparison between the conventional jig, patient‐specific template, and CT‐based navigation. Issue 2 (5th March 2013)
- Record Type:
- Journal Article
- Title:
- Validation of the femoral component placement during hip resurfacing: a comparison between the conventional jig, patient‐specific template, and CT‐based navigation. Issue 2 (5th March 2013)
- Main Title:
- Validation of the femoral component placement during hip resurfacing: a comparison between the conventional jig, patient‐specific template, and CT‐based navigation
- Authors:
- Kitada, Makoto
Sakai, Takashi
Murase, Tsuyoshi
Hanada, Toshihisa
Nakamura, Nobuo
Sugano, Nobuhiko - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="rcs1490-sec-0001" sec-type="section"> <title>Background</title> <p>Appropriate insertion of a femoral guidewire is essential for hip resurfacing. A simulation study was planned using synthetic femoral bone models and the accuracy and precision of femoral guidewire alignment and insertion point were compared between conventional jigs, patient‐specific templates, and computed tomography (CT) based navigation techniques.</p> </sec> <sec id="rcs1490-sec-0002" sec-type="section"> <title>Methods</title> <p>Anteversion, stem‐shaft angle, and the three‐dimensional insertion point were measured postoperative with CT. Errors between planned and postoperative measurement and precision were evaluated.</p> </sec> <sec id="rcs1490-sec-0003" sec-type="section"> <title>Results</title> <p>There were no statistically significant differences in error for anteversion or insertion point, although the mechanical jig showed greater error in the stem‐shaft angle than the others. Patient‐specific template and CT‐based navigation showed good precision with high intraclass correlation (ICC) (template, 0.908 to 1.000; navigation, 0.929 to 0.995) and small root mean square error (RMSE) (0.954 to 2.969; 1.468 to 3.213). The mechanical jig group performance was inferior to the others.</p> </sec> <sec id="rcs1490-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Patient‐specific templates and CT‐based navigation had good accuracy<abstract abstract-type="main"> <title>Abstract</title> <sec id="rcs1490-sec-0001" sec-type="section"> <title>Background</title> <p>Appropriate insertion of a femoral guidewire is essential for hip resurfacing. A simulation study was planned using synthetic femoral bone models and the accuracy and precision of femoral guidewire alignment and insertion point were compared between conventional jigs, patient‐specific templates, and computed tomography (CT) based navigation techniques.</p> </sec> <sec id="rcs1490-sec-0002" sec-type="section"> <title>Methods</title> <p>Anteversion, stem‐shaft angle, and the three‐dimensional insertion point were measured postoperative with CT. Errors between planned and postoperative measurement and precision were evaluated.</p> </sec> <sec id="rcs1490-sec-0003" sec-type="section"> <title>Results</title> <p>There were no statistically significant differences in error for anteversion or insertion point, although the mechanical jig showed greater error in the stem‐shaft angle than the others. Patient‐specific template and CT‐based navigation showed good precision with high intraclass correlation (ICC) (template, 0.908 to 1.000; navigation, 0.929 to 0.995) and small root mean square error (RMSE) (0.954 to 2.969; 1.468 to 3.213). The mechanical jig group performance was inferior to the others.</p> </sec> <sec id="rcs1490-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Patient‐specific templates and CT‐based navigation had good accuracy and precision. The mechanical jig technique was inferior to the others. Copyright © 2013 John Wiley &amp; Sons, Ltd.</p> </sec> </abstract> … (more)
- Is Part Of:
- International journal of medical robotics and computer assisted surgery. Volume 9:Issue 2(2013)
- Journal:
- International journal of medical robotics and computer assisted surgery
- Issue:
- Volume 9:Issue 2(2013)
- Issue Display:
- Volume 9, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 9
- Issue:
- 2
- Issue Sort Value:
- 2013-0009-0002-0000
- Page Start:
- 223
- Page End:
- 229
- Publication Date:
- 2013-03-05
- Subjects:
- Robotics in medicine -- Periodicals
Surgery -- Technological innovations -- Periodicals
Imaging systems in medicine -- Periodicals
617.90285 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1478-596X ↗
http://www.roboticpublications.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/rcs.1490 ↗
- Languages:
- English
- ISSNs:
- 1478-5951
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.347800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3934.xml