A New self-expandable transcatheter aortic valve for transapical implantation: feasibility in acute and chronic animal experiments. (June 2013)
- Record Type:
- Journal Article
- Title:
- A New self-expandable transcatheter aortic valve for transapical implantation: feasibility in acute and chronic animal experiments. (June 2013)
- Main Title:
- A New self-expandable transcatheter aortic valve for transapical implantation: feasibility in acute and chronic animal experiments
- Authors:
- Wendt, Daniel
Pasa, Susanne
Kahlert, Philipp
Delaloye, Stéphane
Al-Rashid, Fadi
Price, Vivien
Jánosi, Rolf-Alexander
Borenstein, Nicolas
Behr, Luc
Konorza, Thomas
Erbel, Raimund
Jakob, Heinz
Thielmann, Matthias - Abstract:
- <abstract> <title>Abstract</title> <p> <italic>Objectives</italic>. Transcatheter aortic valve implantation (TAVI) is currently expanding worldwide, however all available prostheses share some fundamental design drawbacks. We investigated the feasibility, safety and hemodynamic performance of the innovative transapical Acurate TA<sup>™</sup> self-expandable device, which has the unique advantage of offering anatomically correct self-alignment within the aortic root. <italic>Design</italic>. Transapical TAVI was performed in six acute swine and six chronic sheep procedures, with follow-up of 7, 14, 21, 28, 60 and 90 days. TAVI was performed under TEE and angiographic guidance without rapid pacing. <italic>Results</italic>. A partial sternotomy approach was used to access the LV-apex. All valve implantations were performed as planned and all animals survived the implantation procedure. After deployment, no migration, embolization or coronary obstruction was observed during the observation period. Intraoperative TEE examination identified no signs of intravalvular leakage or valve dysfunction. Transvalvular mean pressure gradients were 5.4 ± 2.2 mmHg decreasing during follow-up (1.6 ± 0.8 mmHg, 1.8 ± 0.8 mmHg, 1.3 ± 0.2, 1.8 ± 0.7 mmHg, 1.6 ± 0.8 mmHg), with a slight increase atday 90 (4.0 ± 2.4 mmHg, P &lt; 0.05). Macroscopic examination at necropsy showed correct anatomical positioning of the valve stent without any signs of structural valve deterioration.<abstract> <title>Abstract</title> <p> <italic>Objectives</italic>. Transcatheter aortic valve implantation (TAVI) is currently expanding worldwide, however all available prostheses share some fundamental design drawbacks. We investigated the feasibility, safety and hemodynamic performance of the innovative transapical Acurate TA<sup>™</sup> self-expandable device, which has the unique advantage of offering anatomically correct self-alignment within the aortic root. <italic>Design</italic>. Transapical TAVI was performed in six acute swine and six chronic sheep procedures, with follow-up of 7, 14, 21, 28, 60 and 90 days. TAVI was performed under TEE and angiographic guidance without rapid pacing. <italic>Results</italic>. A partial sternotomy approach was used to access the LV-apex. All valve implantations were performed as planned and all animals survived the implantation procedure. After deployment, no migration, embolization or coronary obstruction was observed during the observation period. Intraoperative TEE examination identified no signs of intravalvular leakage or valve dysfunction. Transvalvular mean pressure gradients were 5.4 ± 2.2 mmHg decreasing during follow-up (1.6 ± 0.8 mmHg, 1.8 ± 0.8 mmHg, 1.3 ± 0.2, 1.8 ± 0.7 mmHg, 1.6 ± 0.8 mmHg), with a slight increase atday 90 (4.0 ± 2.4 mmHg, P &lt; 0.05). Macroscopic examination at necropsy showed correct anatomical positioning of the valve stent without any signs of structural valve deterioration. <italic>Conclusions</italic>. These first results of the innovative self-expandable transapical ACURATE TA<sup>™</sup> device explore the feasibility and safety of anatomically correct off-pump implantation with optimal hemodynamic results.</p> </abstract> … (more)
- Is Part Of:
- Scandinavian cardiovascular journal. Volume 47:Number 3(2013:Jun.)
- Journal:
- Scandinavian cardiovascular journal
- Issue:
- Volume 47:Number 3(2013:Jun.)
- Issue Display:
- Volume 47, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 47
- Issue:
- 3
- Issue Sort Value:
- 2013-0047-0003-0000
- Page Start:
- 145
- Page End:
- 153
- Publication Date:
- 2013-06
- Subjects:
- Cardiovascular system -- Diseases -- Periodicals
617.41 - Journal URLs:
- http://informahealthcare.com/loi/cdv ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/14017431.2012.743675 ↗
- Languages:
- English
- ISSNs:
- 1401-7431
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.472600
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4246.xml