Genotoxic biomonitoring of flowable and non-flowable composite resins in peripheral blood leukocytes. (May 2013)
- Record Type:
- Journal Article
- Title:
- Genotoxic biomonitoring of flowable and non-flowable composite resins in peripheral blood leukocytes. (May 2013)
- Main Title:
- Genotoxic biomonitoring of flowable and non-flowable composite resins in peripheral blood leukocytes
- Authors:
- Tadin, Antonija
Marovic, Danijela
Galic, Nada
Milevoj, Alice
Medvedec Mikic, Ivana
Zeljezic, Davor - Abstract:
- <abstract> <title>Abstract</title> <p> <bold> <italic>Objective.</italic> </bold> Composite restorative materials represent one of the most important groups of materials in contemporary dental practice. However, their incomplete polymerization may lead to monomer-induced genotoxicity. The objective of this study was to evaluate the genotoxicity of three flowable (Filtek Supreme XT Flow, Tetric EvoFlow, Gradia Direct Flo) and three non-flowable dental composite materials (Filtek Z250, Tetric EvoCeram, Gradia Direct Posterior). <bold><italic>Materials and methods.</italic></bold> Genotoxicity assessment of composite materials was carried out <italic>in vitro</italic> in human peripheral blood leukocytes using the alkaline single-cell gel electrophoresis technique (comet assay). Prepared materials were eluted in saline solution for 1 h, 1 day and 5 days. Thereafter leukocyte cultures were treated with different concentrations of eluates obtained from each of the tested dental composite materials. Kruskall-Wallis non-parametric test was used for statistical analysis (<italic>p</italic> &lt; 0.05). <bold><italic>Results.</italic></bold> The tested materials did not show genotoxic effects after exposure of leucocytes to 1 h eluates. Culture treated with 1 day eluates of all tested materials, only at a highest concentration (10<sup>−2</sup>), affected the measured cytogenetic parameters. Of all tested materials, only Filtek Z250 and Filtek Supreme XT Flow did not exhibit a<abstract> <title>Abstract</title> <p> <bold> <italic>Objective.</italic> </bold> Composite restorative materials represent one of the most important groups of materials in contemporary dental practice. However, their incomplete polymerization may lead to monomer-induced genotoxicity. The objective of this study was to evaluate the genotoxicity of three flowable (Filtek Supreme XT Flow, Tetric EvoFlow, Gradia Direct Flo) and three non-flowable dental composite materials (Filtek Z250, Tetric EvoCeram, Gradia Direct Posterior). <bold><italic>Materials and methods.</italic></bold> Genotoxicity assessment of composite materials was carried out <italic>in vitro</italic> in human peripheral blood leukocytes using the alkaline single-cell gel electrophoresis technique (comet assay). Prepared materials were eluted in saline solution for 1 h, 1 day and 5 days. Thereafter leukocyte cultures were treated with different concentrations of eluates obtained from each of the tested dental composite materials. Kruskall-Wallis non-parametric test was used for statistical analysis (<italic>p</italic> &lt; 0.05). <bold><italic>Results.</italic></bold> The tested materials did not show genotoxic effects after exposure of leucocytes to 1 h eluates. Culture treated with 1 day eluates of all tested materials, only at a highest concentration (10<sup>−2</sup>), affected the measured cytogenetic parameters. Of all tested materials, only Filtek Z250 and Filtek Supreme XT Flow did not exhibit a genotoxic effect in cultures that were under the influence of 5 day eluates. <bold><italic>Conclusion.</italic></bold> Tested materials exhibited limited genotoxic activity in peripheral blood leukocytes. Since the effect was observed only in leukocyte cultures treated by 1-day eluates at the highest concentration (10<sup>−2</sup>) and it decreases in cultures exposed to 5 day eluates, it should not pose a significant risk to the human genome.</p> </abstract> … (more)
- Is Part Of:
- Acta odontologica Scandinavica. Volume 71:Number 3/4(2013)
- Journal:
- Acta odontologica Scandinavica
- Issue:
- Volume 71:Number 3/4(2013)
- Issue Display:
- Volume 71, Issue 3/4 (2013)
- Year:
- 2013
- Volume:
- 71
- Issue:
- 3/4
- Issue Sort Value:
- 2013-0071-NaN-0000
- Page Start:
- 923
- Page End:
- 929
- Publication Date:
- 2013-05
- Subjects:
- Dentistry -- Periodicals
617.6005 - Journal URLs:
- http://www.ingentaconnect.com/content/apl/sodo ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/00016357.2012.734419 ↗
- Languages:
- English
- ISSNs:
- 0001-6357
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.630000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3731.xml