Positron‐emission tomography pitfalls related to oral prosthesis12. (9th July 2012)
- Record Type:
- Journal Article
- Title:
- Positron‐emission tomography pitfalls related to oral prosthesis12. (9th July 2012)
- Main Title:
- Positron‐emission tomography pitfalls related to oral prosthesis12
- Authors:
- More, Yogesh
Dusing, Reginald
Counts, Shaheen
Bond, Justin
Tsue, Terrance
Girod, Douglas - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>This case report describes false‐positive positron‐emission tomography/computed tomography (PET/CT) findings related to oral prostheses and its implications in cancer surveillance. In head and neck cancer management, F18‐flurodeoxyglucose (FDG) PET/CT is widely accepted for evaluating treatment response and detecting recurrence. Interpretation of FDG PET/CT images in this setting is often challenging due to various prostheses and reconstruction methods. Following surgery for squamous cell carcinoma of the maxillary alveolus, a 61‐year‐old female had a FDG PET/CT scan on a 7‐month follow‐up that showed high FDG uptake along the resection site. Clinical examination showed no signs of inflammation or recurrence. Repeat FDG PET/CT without the prosthesis was normal. The PET/CT attenuation‐corrected images demonstrated high FDG uptake (standardized uptake value: 11.6) along the resection site corresponding to contrast‐enhanced CT images of the lesion. PET/CT nonattenuation‐corrected images also confirmed increased activity. Repeat PET/CT without the prosthesis was normal. FDG is not tumor specific; it can accumulate in inflammation, infection, and post‐therapy settings. Metallic and high‐density prostheses show radial artifacts on CT and falsely elevated FDG uptake on PET/ CT in adjacent areas. Salivary pooling may concentrate FDG. The presence of oral prostheses has not been described as a cause of this high<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>This case report describes false‐positive positron‐emission tomography/computed tomography (PET/CT) findings related to oral prostheses and its implications in cancer surveillance. In head and neck cancer management, F18‐flurodeoxyglucose (FDG) PET/CT is widely accepted for evaluating treatment response and detecting recurrence. Interpretation of FDG PET/CT images in this setting is often challenging due to various prostheses and reconstruction methods. Following surgery for squamous cell carcinoma of the maxillary alveolus, a 61‐year‐old female had a FDG PET/CT scan on a 7‐month follow‐up that showed high FDG uptake along the resection site. Clinical examination showed no signs of inflammation or recurrence. Repeat FDG PET/CT without the prosthesis was normal. The PET/CT attenuation‐corrected images demonstrated high FDG uptake (standardized uptake value: 11.6) along the resection site corresponding to contrast‐enhanced CT images of the lesion. PET/CT nonattenuation‐corrected images also confirmed increased activity. Repeat PET/CT without the prosthesis was normal. FDG is not tumor specific; it can accumulate in inflammation, infection, and post‐therapy settings. Metallic and high‐density prostheses show radial artifacts on CT and falsely elevated FDG uptake on PET/ CT in adjacent areas. Salivary pooling may concentrate FDG. The presence of oral prostheses has not been described as a cause of this high level of activity. PET/CT images that demonstrate intense activity corresponding to dense structures should be viewed with caution. A detailed history and physical exam as well as knowledge of artifacts are pertinent for the managing physician. Laryngoscope, 2012</p> </abstract> … (more)
- Is Part Of:
- Laryngoscope. Volume 123:Number 2(2013:Feb.)
- Journal:
- Laryngoscope
- Issue:
- Volume 123:Number 2(2013:Feb.)
- Issue Display:
- Volume 123, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 123
- Issue:
- 2
- Issue Sort Value:
- 2013-0123-0002-0000
- Page Start:
- 404
- Page End:
- 406
- Publication Date:
- 2012-07-09
- Subjects:
- Otolaryngology -- Periodicals
617.51005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1531-4995/issues ↗
http://www.interscience.wiley.com/jpages/0023-852X ↗
http://www.laryngoscope.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/lary.23423 ↗
- Languages:
- English
- ISSNs:
- 0023-852X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5156.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3877.xml