Elastic hysteresis in human eyes is an age‐dependent value. (21st August 2012)
- Record Type:
- Journal Article
- Title:
- Elastic hysteresis in human eyes is an age‐dependent value. (21st August 2012)
- Main Title:
- Elastic hysteresis in human eyes is an age‐dependent value
- Authors:
- Ishii, Kotaro
Saito, Kei
Kameda, Toshihiro
Oshika, Tetsuro - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>A<sc>bstract</sc></title> <p> <bold>Background: </bold> The elastic hysteresis phenomenon is observed when cyclic loading is applied to a viscoelastic system. The purpose of this study was to quantitatively evaluate elastic hysteresis in living human eyes against an external force.</p> <p> <bold>Design: </bold> Prospective case series.</p> <p> <bold>Participants: </bold> Twenty‐four eyes of 24 normal human subjects (mean age: 41.5 ± 10.6 years) were recruited.</p> <p> <bold>Methods: </bold> A non‐contact tonometry process was recorded with a high‐speed camera. Central corneal thickness, corneal thickness at 4 mm from the centre, corneal curvature and anterior chamber depth were measured. Intraocular pressure was also measured using Goldmann applanation tonometry and dynamic contour tonometer.</p> <p> <bold>Main Outcome Measures: </bold> Energy loss due to elastic hysteresis was calculated and graphed.</p> <p> <bold>Results: </bold> The mean central corneal thickness was 552.5 ± 36.1 µm, corneal curvature was 7.84 ± 0.26 mm and anterior chamber depth was 2.83 ± 0.29 mm. The mean Goldmann applanation tonometry‐intraocular pressure was 14.2 ± 2.7 mmHg and dynamic contour tonometer‐intraocular pressure was 16.3 ± 3.5 mmHg. The mean energy loss due to elastic hysteresis was 3.90 × 10<sup>−6</sup> ± 2.49 × 10<sup>−6</sup> Nm. Energy loss due to elastic hysteresis correlated significantly with age (Pearson correlation<abstract abstract-type="main" xml:lang="en"> <title>A<sc>bstract</sc></title> <p> <bold>Background: </bold> The elastic hysteresis phenomenon is observed when cyclic loading is applied to a viscoelastic system. The purpose of this study was to quantitatively evaluate elastic hysteresis in living human eyes against an external force.</p> <p> <bold>Design: </bold> Prospective case series.</p> <p> <bold>Participants: </bold> Twenty‐four eyes of 24 normal human subjects (mean age: 41.5 ± 10.6 years) were recruited.</p> <p> <bold>Methods: </bold> A non‐contact tonometry process was recorded with a high‐speed camera. Central corneal thickness, corneal thickness at 4 mm from the centre, corneal curvature and anterior chamber depth were measured. Intraocular pressure was also measured using Goldmann applanation tonometry and dynamic contour tonometer.</p> <p> <bold>Main Outcome Measures: </bold> Energy loss due to elastic hysteresis was calculated and graphed.</p> <p> <bold>Results: </bold> The mean central corneal thickness was 552.5 ± 36.1 µm, corneal curvature was 7.84 ± 0.26 mm and anterior chamber depth was 2.83 ± 0.29 mm. The mean Goldmann applanation tonometry‐intraocular pressure was 14.2 ± 2.7 mmHg and dynamic contour tonometer‐intraocular pressure was 16.3 ± 3.5 mmHg. The mean energy loss due to elastic hysteresis was 3.90 × 10<sup>−6</sup> ± 2.49 × 10<sup>−6</sup> Nm. Energy loss due to elastic hysteresis correlated significantly with age (Pearson correlation coefficient = 0.596, <italic>P</italic> = 0.0016). There were no significant correlations between energy loss due to elastic hysteresis and other measurements.</p> <p> <bold>Conclusion: </bold> Energy loss due to elastic hysteresis in the eyes of subjects was found to positively correlate with age, independent of anterior eye structure or intraocular pressure. Therefore, it is believed that the viscosity of the eye increases with age.</p> </abstract> … (more)
- Is Part Of:
- Clinical & experimental ophthalmology. Volume 41:Number 1(2013)
- Journal:
- Clinical & experimental ophthalmology
- Issue:
- Volume 41:Number 1(2013)
- Issue Display:
- Volume 41, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 41
- Issue:
- 1
- Issue Sort Value:
- 2013-0041-0001-0000
- Page Start:
- 6
- Page End:
- 11
- Publication Date:
- 2012-08-21
- Subjects:
- Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1442-6404&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/j.1442-9071.2012.02830.x ↗
- Languages:
- English
- ISSNs:
- 1442-6404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.251920
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4287.xml