Influence of adhesive point dimension and splint type on splint rigidity – Evaluation by the dynamic Periotest method. Issue 3 (22nd July 2012)
- Record Type:
- Journal Article
- Title:
- Influence of adhesive point dimension and splint type on splint rigidity – Evaluation by the dynamic Periotest method. Issue 3 (22nd July 2012)
- Main Title:
- Influence of adhesive point dimension and splint type on splint rigidity – Evaluation by the dynamic Periotest method
- Authors:
- Franz, Florian
Potapov, Sergej
Petschelt, Anselm
Berthold, Christine - Abstract:
- <abstract abstract-type="main" id="edt1164-abs-0001"> <title>Abstract</title> <sec id="edt1164-sec-0001" sec-type="section"> <title>Aim</title> <p>To evaluate the influence of adhesive point dimension and splint type on the rigidity of wire‐composite splints <italic>in vitro</italic>.</p> </sec> <sec id="edt1164-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>A custom‐made artificial model was used. The two central incisors served as injured teeth (degrees of loosening III and II) and the two lateral incisors as non‐injured teeth (physiological mobility). Horizontal and vertical tooth mobilities were investigated before and after splinting with the Periotest<sup>®</sup> method; the percent change was taken as the relative splint effect. Teeth were splinted with three types of wire‐composite splints: Dentaflex (0.45 mm), Strengtheners (0.8 × 1.8 mm), and Dentaflex completely covered with composite. Four adhesive point dimensions (2, 3, 4, and 5 mm) were evaluated. Normal distribution was tested with the Kolmogorov–Smirnov test. Differences were evaluated with the <sc>anova</sc> and <italic>post hoc</italic> tests for pair‐wise comparisons. Significance level was set at 0.05.</p> </sec> <sec id="edt1164-sec-0003" sec-type="section"> <title>Results</title> <p>The adhesive point dimension did not influence splint rigidity, in general (<italic> P </italic> = 0.288). Significant effects were found in non‐injured teeth with the Dentaflex (<italic> P<abstract abstract-type="main" id="edt1164-abs-0001"> <title>Abstract</title> <sec id="edt1164-sec-0001" sec-type="section"> <title>Aim</title> <p>To evaluate the influence of adhesive point dimension and splint type on the rigidity of wire‐composite splints <italic>in vitro</italic>.</p> </sec> <sec id="edt1164-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>A custom‐made artificial model was used. The two central incisors served as injured teeth (degrees of loosening III and II) and the two lateral incisors as non‐injured teeth (physiological mobility). Horizontal and vertical tooth mobilities were investigated before and after splinting with the Periotest<sup>®</sup> method; the percent change was taken as the relative splint effect. Teeth were splinted with three types of wire‐composite splints: Dentaflex (0.45 mm), Strengtheners (0.8 × 1.8 mm), and Dentaflex completely covered with composite. Four adhesive point dimensions (2, 3, 4, and 5 mm) were evaluated. Normal distribution was tested with the Kolmogorov–Smirnov test. Differences were evaluated with the <sc>anova</sc> and <italic>post hoc</italic> tests for pair‐wise comparisons. Significance level was set at 0.05.</p> </sec> <sec id="edt1164-sec-0003" sec-type="section"> <title>Results</title> <p>The adhesive point dimension did not influence splint rigidity, in general (<italic> P </italic> = 0.288). Significant effects were found in non‐injured teeth with the Dentaflex (<italic> P </italic> &lt; 0.001) and in injured teeth with the Strengtheners (<italic> P </italic> &lt; 0.001). The Strengtheners splint rigidity increased significantly with increasing adhesive point dimensions. The three splints showed significantly different effects at 5‐mm adhesive point dimension (<italic> P </italic> &lt; 0.001).</p> </sec> <sec id="edt1164-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Splint rigidity for injured teeth was influenced by adhesive point dimension only when splinting with Strengtheners. We recommend adapting splint rigidity by selecting different wires and reducing the adhesive point dimension to a minimum. Dentaflex can be used for flexible splinting, Strengtheners, and composite covered Dentaflex for rigid splinting.</p> </sec> </abstract> … (more)
- Is Part Of:
- Dental traumatology. Volume 29:Issue 3(2013:Jun.)
- Journal:
- Dental traumatology
- Issue:
- Volume 29:Issue 3(2013:Jun.)
- Issue Display:
- Volume 29, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 29
- Issue:
- 3
- Issue Sort Value:
- 2013-0029-0003-0000
- Page Start:
- 203
- Page End:
- 211
- Publication Date:
- 2012-07-22
- Subjects:
- Teeth -- Wounds and injuries -- Periodicals
Dentistry, Operative -- Periodicals
Traumatology -- Periodicals
Endodontics -- Periodicals
617.6 - Journal URLs:
- http://www.blackwell-synergy.com/loi/edt ↗
http://www.blackwellpublishing.com/journal.asp?ref=1600-4469 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-9657 ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1600-4469;screen=info;ECOIP ↗ - DOI:
- 10.1111/j.1600-9657.2012.01164.x ↗
- Languages:
- English
- ISSNs:
- 1600-4469
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.512500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3028.xml