MAGNETIC RESONANCE IMAGING OF THE CANINE ABDOMEN: EFFECT OF PULSE SEQUENCE ON DIAGNOSTIC QUALITY. Issue 3 (14th March 2013)
- Record Type:
- Journal Article
- Title:
- MAGNETIC RESONANCE IMAGING OF THE CANINE ABDOMEN: EFFECT OF PULSE SEQUENCE ON DIAGNOSTIC QUALITY. Issue 3 (14th March 2013)
- Main Title:
- MAGNETIC RESONANCE IMAGING OF THE CANINE ABDOMEN: EFFECT OF PULSE SEQUENCE ON DIAGNOSTIC QUALITY
- Authors:
- Manley, Rebecca
Matthews, Andrea R.
Morandi, Federica
Henry, George A.
DeAnna, Katherine H.
Conklin, Gordon
Reed, Ann - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Motion artifact is an important limiting factor for abdominal magnetic resonance imaging (MRI) in veterinary patients. The purpose of this study was to determine the effects of pulse sequence on abdominal MRI diagnostic quality in dogs. Ten normal dogs were each scanned using 16 MRI pulse sequences. Sequences included breath‐holding sequences, respiratory navigation sequences, and traditional spin‐echo sequences. Four observers independently scored diagnostic quality for each sequence based on the appearance of specific organs, overall diagnostic quality, and degree of artifactual interference. Signal‐to‐noise ratio and contrast‐to‐noise ratio were also calculated for each sequence. The sequence with the highest overall mean diagnostic quality score was the dorsal T2 turbo spin echo (TSE) with fat saturation and breath‐holding. The sequence with the lowest mean diagnostic quality score was the dorsal T2 fast spin echo. The sequence with the highest signal‐to‐noise ratio for all evaluated organs was the sagittal T1 spin echo. Signal‐to‐noise and contrast‐to‐noise ratios did not correlate with subjective assessment of overall diagnostic quality for the majority of the sequences evaluated (<italic>P</italic> &lt; 0.05). The three sequences considered to have the highest diagnostic quality for the cranial abdomen were the dorsal T2 TSE with fat saturation and breath‐hold, transverse T1 turbo<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Motion artifact is an important limiting factor for abdominal magnetic resonance imaging (MRI) in veterinary patients. The purpose of this study was to determine the effects of pulse sequence on abdominal MRI diagnostic quality in dogs. Ten normal dogs were each scanned using 16 MRI pulse sequences. Sequences included breath‐holding sequences, respiratory navigation sequences, and traditional spin‐echo sequences. Four observers independently scored diagnostic quality for each sequence based on the appearance of specific organs, overall diagnostic quality, and degree of artifactual interference. Signal‐to‐noise ratio and contrast‐to‐noise ratio were also calculated for each sequence. The sequence with the highest overall mean diagnostic quality score was the dorsal T2 turbo spin echo (TSE) with fat saturation and breath‐holding. The sequence with the lowest mean diagnostic quality score was the dorsal T2 fast spin echo. The sequence with the highest signal‐to‐noise ratio for all evaluated organs was the sagittal T1 spin echo. Signal‐to‐noise and contrast‐to‐noise ratios did not correlate with subjective assessment of overall diagnostic quality for the majority of the sequences evaluated (<italic>P</italic> &lt; 0.05). The three sequences considered to have the highest diagnostic quality for the cranial abdomen were the dorsal T2 TSE with fat saturation and breath‐hold, transverse T1 turbo fast low‐angle shot gradient echo with breath‐hold, and dorsal T2 half‐Fourier acquisition single shot TSE with respiratory navigation. These sequences had short acquisition times, yielded studies of similar diagnostic quality, provided complementary information, and are therefore recommended for routine canine abdominal MRI protocols.</p> </abstract> … (more)
- Is Part Of:
- Veterinary radiology & ultrasound. Volume 54:Issue 3(2013)
- Journal:
- Veterinary radiology & ultrasound
- Issue:
- Volume 54:Issue 3(2013)
- Issue Display:
- Volume 54, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 54
- Issue:
- 3
- Issue Sort Value:
- 2013-0054-0003-0000
- Page Start:
- 253
- Page End:
- 262
- Publication Date:
- 2013-03-14
- Subjects:
- Veterinary radiology -- Periodicals
Radiologie vétérinaire -- Périodiques
Échographie vétérinaire -- Périodiques
Radiography -- Periodicals
Ultrasonography -- Periodicals
Diagnosis -- Periodicals
Veterinary Medicine -- Periodicals
Societies, Medical -- Periodicals
636.089607 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1740-8261 ↗
http://www.blackwell-synergy.com/loi/vru ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1058-8183;screen=info;ECOIP ↗
http://www.blackwell-synergy.com/loi/vru ↗ - DOI:
- 10.1111/vru.12017 ↗
- Languages:
- English
- ISSNs:
- 1058-8183
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9229.281000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3531.xml