Is basal ultrasensitive measurement of calcitonin capable of substituting for the pentagastrin‐stimulation test?. (25th January 2013)
- Record Type:
- Journal Article
- Title:
- Is basal ultrasensitive measurement of calcitonin capable of substituting for the pentagastrin‐stimulation test?. (25th January 2013)
- Main Title:
- Is basal ultrasensitive measurement of calcitonin capable of substituting for the pentagastrin‐stimulation test?
- Authors:
- Pina, Géraldine
Dubois, Séverine
Murat, Arnaud
Berger, Nicole
Niccoli, Patricia
Peix, Jean‐Louis
Cohen, Régis
Guillausseau, Claudine
Charrie, Anne
Chabre, Olivier
Cornu, Catherine
Borson‐Chazot, Françoise
Rohmer, Vincent - Abstract:
- <abstract abstract-type="main" xml:lang="en" id="cen12001-abs-0001"> <title>Summary</title> <sec id="cen12001-sec-0001" sec-type="section"> <title>Objective</title> <p>To evaluate a second‐generation assay for basal serum calcitonin (CT) measurements compared with the pentagastrin‐stimulation test for the diagnosis of inherited medullary thyroid carcinoma (MTC) and the follow‐up of patients with MTC after surgery. Recent American Thyroid Association recommendations suggest the use of basal CT alone to diagnose and assess follow‐up of MTC as the pentagastrin (Pg) test is unavailable in many countries.</p> </sec> <sec id="cen12001-sec-0002" sec-type="section"> <title>Design</title> <p>Multicentric prospective study.</p> </sec> <sec id="cen12001-sec-0003" sec-type="section"> <title>Patients</title> <p>A total of 162 patients with basal CT &lt;10 ng/l were included: 54 asymptomatic patients harboured noncysteine 'rearranged during transfection' (<italic>RET</italic>) proto‐oncogene mutations and 108 patients had entered follow‐up of MTC after surgery.</p> </sec> <sec id="cen12001-sec-0004" sec-type="section"> <title>Measurement</title> <p>All patients underwent basal and Pg‐stimulated CT measurements using a second‐generation assay with 5‐ng/l functional sensitivity.</p> </sec> <sec id="cen12001-sec-0005" sec-type="section"> <title>Results</title> <p>Ninety‐five per cent of patients with basal CT ≥5 ng/l and 25% of patients with basal CT &lt;5 ng/l had a positive Pg‐stimulation<abstract abstract-type="main" xml:lang="en" id="cen12001-abs-0001"> <title>Summary</title> <sec id="cen12001-sec-0001" sec-type="section"> <title>Objective</title> <p>To evaluate a second‐generation assay for basal serum calcitonin (CT) measurements compared with the pentagastrin‐stimulation test for the diagnosis of inherited medullary thyroid carcinoma (MTC) and the follow‐up of patients with MTC after surgery. Recent American Thyroid Association recommendations suggest the use of basal CT alone to diagnose and assess follow‐up of MTC as the pentagastrin (Pg) test is unavailable in many countries.</p> </sec> <sec id="cen12001-sec-0002" sec-type="section"> <title>Design</title> <p>Multicentric prospective study.</p> </sec> <sec id="cen12001-sec-0003" sec-type="section"> <title>Patients</title> <p>A total of 162 patients with basal CT &lt;10 ng/l were included: 54 asymptomatic patients harboured noncysteine 'rearranged during transfection' (<italic>RET</italic>) proto‐oncogene mutations and 108 patients had entered follow‐up of MTC after surgery.</p> </sec> <sec id="cen12001-sec-0004" sec-type="section"> <title>Measurement</title> <p>All patients underwent basal and Pg‐stimulated CT measurements using a second‐generation assay with 5‐ng/l functional sensitivity.</p> </sec> <sec id="cen12001-sec-0005" sec-type="section"> <title>Results</title> <p>Ninety‐five per cent of patients with basal CT ≥5 ng/l and 25% of patients with basal CT &lt;5 ng/l had a positive Pg‐stimulation test (Pg CT &gt;10 ng/l). Compared with the reference Pg test, basal CT ≥5 ng/l had 99% specificity, a 95%‐positive predictive value but only 35% sensitivity (<italic>P </italic>&lt;<italic> </italic>0·0001). Overall, there were 31% less false‐negative results using a 5‐ng/l threshold for basal CT instead of the previously used 10‐ng/l threshold.</p> </sec> <sec id="cen12001-sec-0006" sec-type="section"> <title>Conclusion</title> <p>The ultrasensitive CT assay reduces the false‐negative rate of basal CT measurements when diagnosing familial MTC and in postoperative follow‐up compared with previously used assays. However, its sensitivity to detect C‐cell disease remains lower than that of the Pg‐stimulation test.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical endocrinology. Volume 78:Number 3(2013:Mar.)
- Journal:
- Clinical endocrinology
- Issue:
- Volume 78:Number 3(2013:Mar.)
- Issue Display:
- Volume 78, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 78
- Issue:
- 3
- Issue Sort Value:
- 2013-0078-0003-0000
- Page Start:
- 358
- Page End:
- 364
- Publication Date:
- 2013-01-25
- Subjects:
- Endocrinology -- Periodicals
616.4005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2265 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/cen.12001 ↗
- Languages:
- English
- ISSNs:
- 0300-0664
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.278000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3240.xml