Evaluation of Mindray BC‐3600 hematology analyzer in a university hospital. Issue 1 (23rd August 2012)
- Record Type:
- Journal Article
- Title:
- Evaluation of Mindray BC‐3600 hematology analyzer in a university hospital. Issue 1 (23rd August 2012)
- Main Title:
- Evaluation of Mindray BC‐3600 hematology analyzer in a university hospital
- Authors:
- Shu, G.
Lu, H.
Du, H.
Shi, J.
Wu, G. - Abstract:
- <abstract abstract-type="main" id="ijlh1464-abs-0001"> <title>Summary</title> <sec id="ijlh1464-sec-0001" sec-type="section"> <title>Introduction</title> <p>The BC‐3600 Auto Hematology Analyzer (hereinafter call BC‐3600) is a quantitative, automated hematology analyzer and leukocyte differential counter for In Vitro Diagnostic Use in clinical laboratories.</p> </sec> <sec id="ijlh1464-sec-0002" sec-type="section"> <title>Methods</title> <p>The analyzer was evaluated and compared with the Mindray BC‐3200 3‐part differential (BC‐3200) and Sysmex XE‐2100 5‐part differential (XE‐2100) Hematology Analyzer in the hematology laboratory of a university hospital. The BC‐3600 was evaluated according to guidelines published by Clinical and Laboratory Standards Institute (CLSI), the International Committee for Standardization in Hematology (ICSH), and Department of Food and Drug Administration (FDA).</p> </sec> <sec id="ijlh1464-sec-0003" sec-type="section"> <title>Results</title> <p>There were no background, minimal carryover (&lt;0.5%), and excellent linearity for white blood cell (WBC), hemoglobin (Hb) level, red blood cell (RBC), and platelet (PLT) counts (<italic>r</italic> &gt; 0.999). Precision was good at all levels for the routine cell blood count (CBC) parameters: CV% being ≤2.0, except for platelet count (PLT) at the low level with CV% of ≤5.0% and WBC at the low level with CV% of &lt;3.0%. Correlation between the BC‐3600 and BC‐3200, XE‐2100 were excellent<abstract abstract-type="main" id="ijlh1464-abs-0001"> <title>Summary</title> <sec id="ijlh1464-sec-0001" sec-type="section"> <title>Introduction</title> <p>The BC‐3600 Auto Hematology Analyzer (hereinafter call BC‐3600) is a quantitative, automated hematology analyzer and leukocyte differential counter for In Vitro Diagnostic Use in clinical laboratories.</p> </sec> <sec id="ijlh1464-sec-0002" sec-type="section"> <title>Methods</title> <p>The analyzer was evaluated and compared with the Mindray BC‐3200 3‐part differential (BC‐3200) and Sysmex XE‐2100 5‐part differential (XE‐2100) Hematology Analyzer in the hematology laboratory of a university hospital. The BC‐3600 was evaluated according to guidelines published by Clinical and Laboratory Standards Institute (CLSI), the International Committee for Standardization in Hematology (ICSH), and Department of Food and Drug Administration (FDA).</p> </sec> <sec id="ijlh1464-sec-0003" sec-type="section"> <title>Results</title> <p>There were no background, minimal carryover (&lt;0.5%), and excellent linearity for white blood cell (WBC), hemoglobin (Hb) level, red blood cell (RBC), and platelet (PLT) counts (<italic>r</italic> &gt; 0.999). Precision was good at all levels for the routine cell blood count (CBC) parameters: CV% being ≤2.0, except for platelet count (PLT) at the low level with CV% of ≤5.0% and WBC at the low level with CV% of &lt;3.0%. Correlation between the BC‐3600 and BC‐3200, XE‐2100 were excellent (<italic>r</italic> &gt; 0.99) for all major CBC parameters.</p> </sec> <sec id="ijlh1464-sec-0004" sec-type="section"> <title>Conclusion</title> <p>It is concluded that the overall performance of the BC‐3600 is excellent and compares well with that of BC‐3200 and XE‐2100.</p> </sec> </abstract> … (more)
- Is Part Of:
- International journal of laboratory hematology. Volume 35:Issue 1(2013:Feb.)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 35:Issue 1(2013:Feb.)
- Issue Display:
- Volume 35, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 35
- Issue:
- 1
- Issue Sort Value:
- 2013-0035-0001-0000
- Page Start:
- 61
- Page End:
- 69
- Publication Date:
- 2012-08-23
- Subjects:
- Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/j.1751-553X.2012.01464.x ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3959.xml