Cyclic fatigue resistance of two reciprocating nickel–titanium instruments after immersion in sodium hypochlorite. (26th July 2012)
- Record Type:
- Journal Article
- Title:
- Cyclic fatigue resistance of two reciprocating nickel–titanium instruments after immersion in sodium hypochlorite. (26th July 2012)
- Main Title:
- Cyclic fatigue resistance of two reciprocating nickel–titanium instruments after immersion in sodium hypochlorite
- Authors:
- Pedullà, E.
Grande, N. M.
Plotino, G.
Palermo, F.
Gambarini, G.
Rapisarda, E. - Abstract:
- <abstract abstract-type="main" id="iej2100-abs-0001"> <title>Abstract</title> <sec id="iej2100-sec-0001" sec-type="section"> <title>Aim</title> <p>To assess resistance to cyclic fatigue of reciprocating nickel–titanium ( NiTi ) files (Reciproc and WaveOne) after immersion in NaOCl solution over several time periods.</p> </sec> <sec id="iej2100-sec-0002" sec-type="section"> <title>Methodology</title> <p>A total of 90 new Reciproc R25 and WaveOne Primary were tested. The 45 files of the same brand were randomly assigned to three groups (<italic>n</italic> = 15) and submitted to the following immersion protocol in 5% NaOCl at 37 °C for 16 mm: no immersion (control), 1 or 5 min dynamically. The dynamic immersion and the following cyclic fatigue tests were performed using the appropriate preset reciprocation modes ('RECIPROC ALL' or 'WAVEONE ALL') in a specially designed endodontic motor. Resistance to cyclic fatigue was determined by recording time to fracture (TtF) in a stainless steel artificial canal with a 60° angle of curvature and 5 mm radius of curvature. The artificial canal was manufactured reproducing the instrument's size and taper. Data were analysed by 2‐way analyses of variance.</p> </sec> <sec id="iej2100-sec-0003" sec-type="section"> <title>Results</title> <p>Resistance to cyclic fatigue of the same NiTi file was not significantly affected by immersion in NaOCl . Reciproc R25 was associated with a higher cyclic fatigue resistance in all groups compared to WaveOne<abstract abstract-type="main" id="iej2100-abs-0001"> <title>Abstract</title> <sec id="iej2100-sec-0001" sec-type="section"> <title>Aim</title> <p>To assess resistance to cyclic fatigue of reciprocating nickel–titanium ( NiTi ) files (Reciproc and WaveOne) after immersion in NaOCl solution over several time periods.</p> </sec> <sec id="iej2100-sec-0002" sec-type="section"> <title>Methodology</title> <p>A total of 90 new Reciproc R25 and WaveOne Primary were tested. The 45 files of the same brand were randomly assigned to three groups (<italic>n</italic> = 15) and submitted to the following immersion protocol in 5% NaOCl at 37 °C for 16 mm: no immersion (control), 1 or 5 min dynamically. The dynamic immersion and the following cyclic fatigue tests were performed using the appropriate preset reciprocation modes ('RECIPROC ALL' or 'WAVEONE ALL') in a specially designed endodontic motor. Resistance to cyclic fatigue was determined by recording time to fracture (TtF) in a stainless steel artificial canal with a 60° angle of curvature and 5 mm radius of curvature. The artificial canal was manufactured reproducing the instrument's size and taper. Data were analysed by 2‐way analyses of variance.</p> </sec> <sec id="iej2100-sec-0003" sec-type="section"> <title>Results</title> <p>Resistance to cyclic fatigue of the same NiTi file was not significantly affected by immersion in NaOCl . Reciproc R25 was associated with a higher cyclic fatigue resistance in all groups compared to WaveOne Primary (<italic>P</italic> &lt; 0.0001).</p> </sec> <sec id="iej2100-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Reciprocating dynamic immersion in NaOCl for 1 or 5 min did not reduce the cyclic fatigue resistance of NiTi files significantly. However, the type of reciprocating instrument influenced cyclic fatigue resistance with Reciproc R25 being more resistant than WaveOne Primary.</p> </sec> </abstract> … (more)
- Is Part Of:
- International endontic journal. Volume 46:Number 2(2013:Feb.)
- Journal:
- International endontic journal
- Issue:
- Volume 46:Number 2(2013:Feb.)
- Issue Display:
- Volume 46, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 46
- Issue:
- 2
- Issue Sort Value:
- 2013-0046-0002-0000
- Page Start:
- 155
- Page End:
- 159
- Publication Date:
- 2012-07-26
- Subjects:
- Endodontics -- Periodicals
617.6342 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2591 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/j.1365-2591.2012.02100.x ↗
- Languages:
- English
- ISSNs:
- 0143-2885
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4539.975000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3967.xml