Vaginal degeneration following implantation of synthetic mesh with increased stiffness. Issue 2 (14th December 2012)
- Record Type:
- Journal Article
- Title:
- Vaginal degeneration following implantation of synthetic mesh with increased stiffness. Issue 2 (14th December 2012)
- Main Title:
- Vaginal degeneration following implantation of synthetic mesh with increased stiffness
- Authors:
- Liang, R
Abramowitch, S
Knight, K
Palcsey, S
Nolfi, A
Feola, A
Stein, S
Moalli, PA - Abstract:
- <abstract abstract-type="main" id="bjo12085-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="bjo12085-sec-0001" sec-type="section"> <title>Objective</title> <p>To compare the impact of the prototype prolapse mesh Gynemesh PS with that of two new‐generation lower stiffness meshes, UltraPro and SmartMesh, on vaginal morphology and structural composition.</p> </sec> <sec id="bjo12085-sec-0002" sec-type="section"> <title>Design</title> <p>A mechanistic study employing a nonhuman primate model.</p> </sec> <sec id="bjo12085-sec-0003" sec-type="section"> <title>Setting</title> <p>Magee‐Womens Research Institute at the University of Pittsburgh.</p> </sec> <sec id="bjo12085-sec-0004" sec-type="section"> <title>Population</title> <p>Parous rhesus macaques, with similar age, weight, parity and Pelvic Organ Prolapse‐Questionnaire scores.</p> </sec> <sec id="bjo12085-sec-0005" sec-type="section"> <title>Methods</title> <p>Following Institutional Animal Care Use Committee approval, 50 rhesus macaques were implanted with Gynemesh PS (<italic>n</italic> = 12), UltraPro with its blue line perpendicular to the longitudinal axis of vagina (<italic>n</italic> = 10), UltraPro with its blue line parallel to the longitudinal axis of vagina (<italic>n</italic> = 8) or SmartMesh (<italic>n</italic> = 8) via sacrocolpopexy following hysterectomy. Sham‐operated animals (<italic>n</italic> = 12) served as controls.</p> </sec> <sec id="bjo12085-sec-0006" sec-type="section"><abstract abstract-type="main" id="bjo12085-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="bjo12085-sec-0001" sec-type="section"> <title>Objective</title> <p>To compare the impact of the prototype prolapse mesh Gynemesh PS with that of two new‐generation lower stiffness meshes, UltraPro and SmartMesh, on vaginal morphology and structural composition.</p> </sec> <sec id="bjo12085-sec-0002" sec-type="section"> <title>Design</title> <p>A mechanistic study employing a nonhuman primate model.</p> </sec> <sec id="bjo12085-sec-0003" sec-type="section"> <title>Setting</title> <p>Magee‐Womens Research Institute at the University of Pittsburgh.</p> </sec> <sec id="bjo12085-sec-0004" sec-type="section"> <title>Population</title> <p>Parous rhesus macaques, with similar age, weight, parity and Pelvic Organ Prolapse‐Questionnaire scores.</p> </sec> <sec id="bjo12085-sec-0005" sec-type="section"> <title>Methods</title> <p>Following Institutional Animal Care Use Committee approval, 50 rhesus macaques were implanted with Gynemesh PS (<italic>n</italic> = 12), UltraPro with its blue line perpendicular to the longitudinal axis of vagina (<italic>n</italic> = 10), UltraPro with its blue line parallel to the longitudinal axis of vagina (<italic>n</italic> = 8) or SmartMesh (<italic>n</italic> = 8) via sacrocolpopexy following hysterectomy. Sham‐operated animals (<italic>n</italic> = 12) served as controls.</p> </sec> <sec id="bjo12085-sec-0006" sec-type="section"> <title>Main outcome measures</title> <p>The mesh–vagina complex was removed after 12 weeks and analysed for histomorphology, <italic>in situ</italic> cell apoptosis, total collagen, elastin, glycosaminoglycan content and total collagenase activity. Appropriate statistics and correlation analyses were performed accordingly.</p> </sec> <sec id="bjo12085-sec-0007" sec-type="section"> <title>Results</title> <p>Relative to sham and the two lower stiffness meshes, Gynemesh PS had the greatest negative impact on vaginal histomorphology and composition. Compared with sham, implantation with Gynemesh PS caused substantial thinning of the smooth muscle layer (1557 ± 499 μm versus 866 ± 210 μm, <italic>P</italic> = 0.02), increased apoptosis particularly in the area of the mesh fibres (<italic>P</italic> = 0.01), decreased collagen and elastin content (20%, <italic>P</italic> = 0.03 and 43%, <italic>P</italic> = 0.02, respectively) and increased total collagenase activity (135%, <italic>P</italic> = 0.01). Glycosaminoglycan, a marker of tissue injury, was highest with Gynemesh PS compared with sham and other meshes (<italic>P</italic> = 0.01).</p> </sec> <sec id="bjo12085-sec-0008" sec-type="section"> <title>Conclusion</title> <p>Mesh implantation with the stiffer mesh Gynemesh PS induced a maladaptive remodelling response consistent with vaginal degeneration.</p> </sec> </abstract> … (more)
- Is Part Of:
- BJOG. Volume 120:Issue 2(2013:Feb.)
- Journal:
- BJOG
- Issue:
- Volume 120:Issue 2(2013:Feb.)
- Issue Display:
- Volume 120, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 120
- Issue:
- 2
- Issue Sort Value:
- 2013-0120-0002-0000
- Page Start:
- 233
- Page End:
- 243
- Publication Date:
- 2012-12-14
- Subjects:
- Obstetrics -- Periodicals
Gynecology -- Periodicals
618 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1470-0328&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/1471-0528.12085 ↗
- Languages:
- English
- ISSNs:
- 1470-0328
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2105.748000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4072.xml