Interocular differences in visual latency induced by reduced‐aperture monovision. (28th December 2012)
- Record Type:
- Journal Article
- Title:
- Interocular differences in visual latency induced by reduced‐aperture monovision. (28th December 2012)
- Main Title:
- Interocular differences in visual latency induced by reduced‐aperture monovision
- Authors:
- Plainis, Sotiris
Petratou, Dionysia
Giannakopoulou, Trisevgeni
Radhakrishnan, Hema
Pallikaris, Ioannis G
Charman, W Neil - Abstract:
- <abstract abstract-type="main" id="opo12018-abs-0001"> <title>Abstract</title> <sec id="opo12018-sec-0001" sec-type="section"> <title>Purpose</title> <p>To explore the interocular differences in the temporal responses of the eyes induced by the monocular use of small‐aperture optics designed to aid presbyopes by increasing their depth‐of‐focus.</p> </sec> <sec id="opo12018-sec-0002" sec-type="section"> <title>Methods</title> <p>Monocular and binocular pattern‐reversal visual evoked potentials (VEPs) were measured at a mean photopic field luminance of 30 cd/m<sup>2</sup> in seven normal subjects with either natural pupils or when the non‐dominant eye wore a small‐aperture contact lens (aperture diameter 1.5, 2.5 or 3.5 mm, or an annular opaque stop of inner and outer diameters 1.5 and 4.0 mm respectively). Responses were also measured with varying stimulus luminance (5, 13.9, 27.2 and 45 cd/m<sup>2</sup>) and a fixed 3.0 mm artificial pupil.</p> </sec> <sec id="opo12018-sec-0003" sec-type="section"> <title>Results</title> <p>Mean natural pupil diameters were 4.7 and 4.4 mm under monocular and binocular conditions respectively. The small‐aperture contact lenses reduced the amplitude of the P100 component of the VEP and increased its latency. Inter‐ocular differences in latency rose to about 20–25 ms when the pupil diameter of the non‐dominant eye was reduced to 1.5 mm. The measurements with fixed pupil and varying luminance suggested that the observed effects were explicable<abstract abstract-type="main" id="opo12018-abs-0001"> <title>Abstract</title> <sec id="opo12018-sec-0001" sec-type="section"> <title>Purpose</title> <p>To explore the interocular differences in the temporal responses of the eyes induced by the monocular use of small‐aperture optics designed to aid presbyopes by increasing their depth‐of‐focus.</p> </sec> <sec id="opo12018-sec-0002" sec-type="section"> <title>Methods</title> <p>Monocular and binocular pattern‐reversal visual evoked potentials (VEPs) were measured at a mean photopic field luminance of 30 cd/m<sup>2</sup> in seven normal subjects with either natural pupils or when the non‐dominant eye wore a small‐aperture contact lens (aperture diameter 1.5, 2.5 or 3.5 mm, or an annular opaque stop of inner and outer diameters 1.5 and 4.0 mm respectively). Responses were also measured with varying stimulus luminance (5, 13.9, 27.2 and 45 cd/m<sup>2</sup>) and a fixed 3.0 mm artificial pupil.</p> </sec> <sec id="opo12018-sec-0003" sec-type="section"> <title>Results</title> <p>Mean natural pupil diameters were 4.7 and 4.4 mm under monocular and binocular conditions respectively. The small‐aperture contact lenses reduced the amplitude of the P100 component of the VEP and increased its latency. Inter‐ocular differences in latency rose to about 20–25 ms when the pupil diameter of the non‐dominant eye was reduced to 1.5 mm. The measurements with fixed pupil and varying luminance suggested that the observed effects were explicable in terms of the changes in retinal illuminance produced by the restrictions in pupil area.</p> </sec> <sec id="opo12018-sec-0004" sec-type="section"> <title>Conclusions</title> <p>The anisocoria induced by small‐aperture approaches to aid presbyopes produces marked interocular differences in visual latency. The literature of the Pulfrich effect suggests that such differences can lead to distortions in the perception of relative movement and, in some cases, to possible hazard.</p> </sec> </abstract> … (more)
- Is Part Of:
- Ophthalmic and physiological optics. Volume 33:Number 2(2013:Mar.)
- Journal:
- Ophthalmic and physiological optics
- Issue:
- Volume 33:Number 2(2013:Mar.)
- Issue Display:
- Volume 33, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 33
- Issue:
- 2
- Issue Sort Value:
- 2013-0033-0002-0000
- Page Start:
- 123
- Page End:
- 129
- Publication Date:
- 2012-12-28
- Subjects:
- Ophthalmology -- Periodicals
Physiological optics -- Periodicals
Optometry -- Periodicals
Optics -- Periodicals
Vision -- Periodicals
617.75 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0275-5408&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/opo.12018 ↗
- Languages:
- English
- ISSNs:
- 0275-5408
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6270.870000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3982.xml