Intense Focused Ultrasound Preferentially Stimulates Subcutaneous and Focal Neuropathic Tissue: Preliminary Results. Issue 1 (8th November 2012)
- Record Type:
- Journal Article
- Title:
- Intense Focused Ultrasound Preferentially Stimulates Subcutaneous and Focal Neuropathic Tissue: Preliminary Results. Issue 1 (8th November 2012)
- Main Title:
- Intense Focused Ultrasound Preferentially Stimulates Subcutaneous and Focal Neuropathic Tissue: Preliminary Results
- Authors:
- McClintic, Abbi M.
Dickey, Trevor C.
Gofeld, Michael
Kliot, Michel
Loeser, John D.
Richebe, Philippe
Mourad, Pierre D. - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="pme1510-sec-0001" sec-type="section"> <title>Objective.</title> <p>Potential peripheral sources of pain from subcutaneous tissue can require invasive evocative tests for their localization and assessment. Here, we describe studies whose ultimate goal is development of a noninvasive evocative test for subcutaneous, painful tissue.</p> </sec> <sec id="pme1510-sec-0002" sec-type="section"> <title>Design.</title> <p>We used a rat model of a focal and subcutaneous neuroma to test the hypothesis that intense focused ultrasound can differentiate focal and subcutaneous neuropathic tissue from control tissue. To do so, we first applied intense focused ultrasound (2 MHz, with individual pulses of 0.1 second in duration) to the rat's neuroma while the rat was under light anesthesia. We started with low values of intensity, which we increased until intense focused ultrasound stimulation caused the rat to reliably flick its paw. We then applied that same intense focused ultrasound protocol to control tissue away from the neuroma and assayed for the rat's response to that stimulation.</p> </sec> <sec id="pme1510-sec-0003" sec-type="section"> <title>Results.</title> <p>Intense focused ultrasound of sufficient strength (I<sub>SATA</sub> of 600 +/− 160 W/cm<sup>2</sup>) applied to the neuroma caused the rat to flick its paw, while the same intense focused ultrasound applied millimeters to a centimeter away failed to induce a<abstract abstract-type="main"> <title>Abstract</title> <sec id="pme1510-sec-0001" sec-type="section"> <title>Objective.</title> <p>Potential peripheral sources of pain from subcutaneous tissue can require invasive evocative tests for their localization and assessment. Here, we describe studies whose ultimate goal is development of a noninvasive evocative test for subcutaneous, painful tissue.</p> </sec> <sec id="pme1510-sec-0002" sec-type="section"> <title>Design.</title> <p>We used a rat model of a focal and subcutaneous neuroma to test the hypothesis that intense focused ultrasound can differentiate focal and subcutaneous neuropathic tissue from control tissue. To do so, we first applied intense focused ultrasound (2 MHz, with individual pulses of 0.1 second in duration) to the rat's neuroma while the rat was under light anesthesia. We started with low values of intensity, which we increased until intense focused ultrasound stimulation caused the rat to reliably flick its paw. We then applied that same intense focused ultrasound protocol to control tissue away from the neuroma and assayed for the rat's response to that stimulation.</p> </sec> <sec id="pme1510-sec-0003" sec-type="section"> <title>Results.</title> <p>Intense focused ultrasound of sufficient strength (I<sub>SATA</sub> of 600 +/− 160 W/cm<sup>2</sup>) applied to the neuroma caused the rat to flick its paw, while the same intense focused ultrasound applied millimeters to a centimeter away failed to induce a paw flick.</p> </sec> <sec id="pme1510-sec-0004" sec-type="section"> <title>Conclusion.</title> <p>Successful stimulation of the neuroma by intense focused ultrasound required colocalization of the neuroma and intense focused ultrasound supporting our hypothesis.</p> </sec> </abstract> … (more)
- Is Part Of:
- Pain medicine. Volume 14:Issue 1(2013)
- Journal:
- Pain medicine
- Issue:
- Volume 14:Issue 1(2013)
- Issue Display:
- Volume 14, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 14
- Issue:
- 1
- Issue Sort Value:
- 2013-0014-0001-0000
- Page Start:
- 84
- Page End:
- 92
- Publication Date:
- 2012-11-08
- Subjects:
- Pain -- Periodicals
Pain -- Treatment -- Periodicals
Analgesics -- Periodicals
Pain -- Periodicals
Pain Management -- Periodicals
Douleur -- Périodiques
Douleur -- Traitement -- Périodiques
Analgésiques -- Périodiques
Analgésique
Soulagement de la douleur
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.047205 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1526-2375;screen=info;ECOIP ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1526-4637 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=pme ↗
http://painmedicine.oxfordjournals.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/j.1526-4637.2012.01510.x ↗
- Languages:
- English
- ISSNs:
- 1526-2375
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6333.806000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3328.xml