Repeatability of the measurement of aortic pulse wave velocity (aPWV) in the clinical assessment of arterial stiffness in community-dwelling older patients using the Vicorder® device. (June 2013)
- Record Type:
- Journal Article
- Title:
- Repeatability of the measurement of aortic pulse wave velocity (aPWV) in the clinical assessment of arterial stiffness in community-dwelling older patients using the Vicorder® device. (June 2013)
- Main Title:
- Repeatability of the measurement of aortic pulse wave velocity (aPWV) in the clinical assessment of arterial stiffness in community-dwelling older patients using the Vicorder® device
- Authors:
- McGreevy, Cora
Barry, Miriam
Bennett, Kathleen
Williams, David - Abstract:
- <abstract> <title>Abstract</title> <p> <bold> <italic>Background</italic>.</bold> Pulse wave velocity measured using the Vicorder<sup>®</sup> apparatus is a non-invasive indicator of arterial stiffness. The objective of this study was to assess its repeatability in older patients when used by medical professionals with limited experience of the technique. <bold><italic>Methods</italic>.</bold> Aortic pulse wave velocity (aPWV) was measured using the Vicorder<sup>®</sup> system four times using the conventional pathway and twice by adapted pathway in 25 consecutive ambulant patients (15 male) after they rested supine for 15 min. A nurse and a doctor independently and alternately measured PWV using the same equipment and were blinded to their colleague's PWV readings. 'Within' and 'between' observer differences were assessed using intra-class correlation coefficients (rI) and 95% limits of agreement (95% LoA) derived from Bland-Altman plots. <bold><italic>Results</italic>.</bold> Mean age was 79.8 (mean blood pressure [BP] = 133/69, Mean heart rate [HR]: 70.9). Mean PWV was 11.73 (Standard Deviation [SD] 2.6–3.6). 'Between' and 'within' observer repeatability was high, with rIs ranging from 0.8–0.93. The repeatability index for 'between' nurse and doctor measures was slightly lower (rI = 0.88) when an adapted cuff measure was used in assessing PWV compared to conventional cuff measures (rI = 0.93). Mean PWV readings 'between' observers differed by only 0.094 (95% CI −0.24 to<abstract> <title>Abstract</title> <p> <bold> <italic>Background</italic>.</bold> Pulse wave velocity measured using the Vicorder<sup>®</sup> apparatus is a non-invasive indicator of arterial stiffness. The objective of this study was to assess its repeatability in older patients when used by medical professionals with limited experience of the technique. <bold><italic>Methods</italic>.</bold> Aortic pulse wave velocity (aPWV) was measured using the Vicorder<sup>®</sup> system four times using the conventional pathway and twice by adapted pathway in 25 consecutive ambulant patients (15 male) after they rested supine for 15 min. A nurse and a doctor independently and alternately measured PWV using the same equipment and were blinded to their colleague's PWV readings. 'Within' and 'between' observer differences were assessed using intra-class correlation coefficients (rI) and 95% limits of agreement (95% LoA) derived from Bland-Altman plots. <bold><italic>Results</italic>.</bold> Mean age was 79.8 (mean blood pressure [BP] = 133/69, Mean heart rate [HR]: 70.9). Mean PWV was 11.73 (Standard Deviation [SD] 2.6–3.6). 'Between' and 'within' observer repeatability was high, with rIs ranging from 0.8–0.93. The repeatability index for 'between' nurse and doctor measures was slightly lower (rI = 0.88) when an adapted cuff measure was used in assessing PWV compared to conventional cuff measures (rI = 0.93). Mean PWV readings 'between' observers differed by only 0.094 (95% CI −0.24 to 1.59). <bold><italic>Conclusion</italic>.</bold> When undertaken by operators with limited previous technical experience, both 'within' and 'between' observer repeatability of PWV measurement was high. This method has the potential to be included in the clinical assessment of arterial stiffness in older ambulant patients.</p> </abstract> … (more)
- Is Part Of:
- Scandinavian journal of clinical & laboratory investigation. Volume 73:Number 4(2013)
- Journal:
- Scandinavian journal of clinical & laboratory investigation
- Issue:
- Volume 73:Number 4(2013)
- Issue Display:
- Volume 73, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 73
- Issue:
- 4
- Issue Sort Value:
- 2013-0073-0004-0000
- Page Start:
- 269
- Page End:
- 273
- Publication Date:
- 2013-06
- Subjects:
- Clinical biochemistry -- Periodicals
Physiology, Pathological -- Periodicals
Physiology, Experimental -- Periodicals
Medicine -- Research -- Periodicals
Clinical medicine -- Periodicals
616.0072 - Journal URLs:
- http://informahealthcare.com/loi/clb ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/00365513.2013.770162 ↗
- Languages:
- English
- ISSNs:
- 0036-5513
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3922.xml