Preservation of crestal bone by implant design. A comparative study in minipigs. Issue 3 (19th June 2012)
- Record Type:
- Journal Article
- Title:
- Preservation of crestal bone by implant design. A comparative study in minipigs. Issue 3 (19th June 2012)
- Main Title:
- Preservation of crestal bone by implant design. A comparative study in minipigs
- Authors:
- Heitz‐Mayfield, L. J. A.
Darby, I.
Heitz, F.
Chen, S. - Abstract:
- <abstract abstract-type="main" id="clr2513-abs-0001"> <title>Abstract</title> <sec id="clr2513-sec-0001" sec-type="section"> <title>Objectives</title> <p>To compare crestal bone modeling at three bone level design implants; Astra Tech Osseospeed<sup>™</sup> Implant (AOI), Straumann<sup>®</sup> Bone Level Implant (SBLI) and NobelReplace<sup>™</sup> Tapered Groovy Implant (NBTI).</p> </sec> <sec id="clr2513-sec-0002" sec-type="section"> <title>Materials and methods</title> <p>In 12 minipigs one implant of each design was placed on each side of the mandible with submerged healing. The implant platform was placed at the level of the crest (Group 0), and 1 mm above the crest (Group + 1 mm). In addition, one Straumann<sup>®</sup> Tissue Level Implant STLI was placed as a control on each side of the mandible. At 4 weeks, six animals were sacrificed. In the remaining six animals healing abutments were connected until 12 weeks. Clinical, radiographic, and histologic analyses were made. ANOVA and Mann–Whitney <italic>U</italic>‐tests were used to evaluate differences in bone levels between implant designs.</p> </sec> <sec id="clr2513-sec-0003" sec-type="section"> <title>Results</title> <p>At 4 weeks there was no statistically significant difference in bone changes between implant designs. At 12 weeks implants in Group + 1 mm had minimal bone changes with no differences between implant designs. In Group 0, the AOI and SBLI preserved more crestal bone than NBTI<abstract abstract-type="main" id="clr2513-abs-0001"> <title>Abstract</title> <sec id="clr2513-sec-0001" sec-type="section"> <title>Objectives</title> <p>To compare crestal bone modeling at three bone level design implants; Astra Tech Osseospeed<sup>™</sup> Implant (AOI), Straumann<sup>®</sup> Bone Level Implant (SBLI) and NobelReplace<sup>™</sup> Tapered Groovy Implant (NBTI).</p> </sec> <sec id="clr2513-sec-0002" sec-type="section"> <title>Materials and methods</title> <p>In 12 minipigs one implant of each design was placed on each side of the mandible with submerged healing. The implant platform was placed at the level of the crest (Group 0), and 1 mm above the crest (Group + 1 mm). In addition, one Straumann<sup>®</sup> Tissue Level Implant STLI was placed as a control on each side of the mandible. At 4 weeks, six animals were sacrificed. In the remaining six animals healing abutments were connected until 12 weeks. Clinical, radiographic, and histologic analyses were made. ANOVA and Mann–Whitney <italic>U</italic>‐tests were used to evaluate differences in bone levels between implant designs.</p> </sec> <sec id="clr2513-sec-0003" sec-type="section"> <title>Results</title> <p>At 4 weeks there was no statistically significant difference in bone changes between implant designs. At 12 weeks implants in Group + 1 mm had minimal bone changes with no differences between implant designs. In Group 0, the AOI and SBLI preserved more crestal bone than NBTI (<italic>P</italic> &lt; 0.01). Mean distance from the implant platform to the buccal bone was −0.1 ± 0.2 mm for AOI, −0.3 ± 0.3 mm for SBLI, and −1.0 ± 0.3 mm for NBTI. Mean radiographic bone levels from the implant platform were −0.1 ± 0.4 mm for AOI, 0.0 ± 0.3 mm for SBLI and −0.9 ± 0.8 mm for NBTI.</p> </sec> <sec id="clr2513-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Greater bone preservation was observed for the AOI and SBLI compared with the NBTI.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical oral implants research. Volume 24:Issue 3(2013:Mar.)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 24:Issue 3(2013:Mar.)
- Issue Display:
- Volume 24, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 24
- Issue:
- 3
- Issue Sort Value:
- 2013-0024-0003-0000
- Page Start:
- 243
- Page End:
- 249
- Publication Date:
- 2012-06-19
- Subjects:
- Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/j.1600-0501.2012.02513.x ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: