Clinical Outcome of Dental Implants Placed with High Insertion Torques (Up to 176 Ncm). (20th May 2011)
- Record Type:
- Journal Article
- Title:
- Clinical Outcome of Dental Implants Placed with High Insertion Torques (Up to 176 Ncm). (20th May 2011)
- Main Title:
- Clinical Outcome of Dental Implants Placed with High Insertion Torques (Up to 176 Ncm)
- Authors:
- Khayat, Philippe G.
Arnal, Hélène M.
Tourbah, Bahige I.
Sennerby, Lars - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>ABSTRACT</title> <p> <bold>Background:</bold> Primary stability can be improved by using a tapered implant in a slightly underprepared implant site. This may lead to high compression forces and elevated insertion torques. It has been postulated that disturbance of the local microcirculation may occur, leading to necrosis of the osteocytes and bone resorption.</p> <p> <bold>Purpose:</bold> Report on the clinical outcome of 42 implants placed with an insertion torque equal or greater than 70 Ncm and evaluate bone levels around these implants.</p> <p> <bold>Materials and Methods:</bold> This prospective study included 48 patients treated with 66 4.5 mm diameter Tapered Screw‐Vent implants (Zimmer Dental®, Carlsbad, CA, USA). Maximum insertion torque (MIT) was recorded with an electronic torque measuring device (Tohnichi® STC200CN, Hitachi, Tokyo, Japan).</p> <p>Nine implants (control group) presented MIT between 30 and 50 Ncm (mean = 37.1 Ncm) and 42 implants (experimental group) MIT greater than 70 Ncm (mean = 110.6 Ncm, range: 70.8–176 Ncm). Marginal bone levels were recorded at the time of loading and 1 year later for the two groups.</p> <p> <bold>Results:</bold> After 2–3 months of non‐sumerged healing, all implants were clinically stable. Mean marginal bone resorption was 1.03 mm (SD = 0.44) for the control group (low torque) and 0.72 mm (SD = 0.56) for the experimental group (high torque) at time of loading, and 1.09<abstract abstract-type="main" xml:lang="en"> <title>ABSTRACT</title> <p> <bold>Background:</bold> Primary stability can be improved by using a tapered implant in a slightly underprepared implant site. This may lead to high compression forces and elevated insertion torques. It has been postulated that disturbance of the local microcirculation may occur, leading to necrosis of the osteocytes and bone resorption.</p> <p> <bold>Purpose:</bold> Report on the clinical outcome of 42 implants placed with an insertion torque equal or greater than 70 Ncm and evaluate bone levels around these implants.</p> <p> <bold>Materials and Methods:</bold> This prospective study included 48 patients treated with 66 4.5 mm diameter Tapered Screw‐Vent implants (Zimmer Dental®, Carlsbad, CA, USA). Maximum insertion torque (MIT) was recorded with an electronic torque measuring device (Tohnichi® STC200CN, Hitachi, Tokyo, Japan).</p> <p>Nine implants (control group) presented MIT between 30 and 50 Ncm (mean = 37.1 Ncm) and 42 implants (experimental group) MIT greater than 70 Ncm (mean = 110.6 Ncm, range: 70.8–176 Ncm). Marginal bone levels were recorded at the time of loading and 1 year later for the two groups.</p> <p> <bold>Results:</bold> After 2–3 months of non‐sumerged healing, all implants were clinically stable. Mean marginal bone resorption was 1.03 mm (SD = 0.44) for the control group (low torque) and 0.72 mm (SD = 0.56) for the experimental group (high torque) at time of loading, and 1.09 (SD = 0.62) and 1.24 mm (SD = 0.75), respectively, after 1 year. There were no significant differences between the two groups for bone stability and implant success rate.</p> <p> <bold>Conclusions:</bold> The use of high insertion torques (up to 176 Ncm) did not prevent osseointegration. Marginal bone levels in the control and experimental groups were similar both at the time of loading and 1 year later.</p> </abstract> … (more)
- Is Part Of:
- Clinical implant dentistry and related research. Volume 15:Number 2(2013:Apr.)
- Journal:
- Clinical implant dentistry and related research
- Issue:
- Volume 15:Number 2(2013:Apr.)
- Issue Display:
- Volume 15, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 15
- Issue:
- 2
- Issue Sort Value:
- 2013-0015-0002-0000
- Page Start:
- 227
- Page End:
- 233
- Publication Date:
- 2011-05-20
- Subjects:
- Dental implants -- Periodicals
Dental Implantation -- Periodicals
Dental Implants -- Periodicals
617.693 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/j.1708-8208.2011.00351.x ↗
- Languages:
- English
- ISSNs:
- 1523-0899
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.293825
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3377.xml