Noninvasive methods for haemoglobin screening in prospective blood donors. Issue 2 (19th April 2013)
- Record Type:
- Journal Article
- Title:
- Noninvasive methods for haemoglobin screening in prospective blood donors. Issue 2 (19th April 2013)
- Main Title:
- Noninvasive methods for haemoglobin screening in prospective blood donors
- Authors:
- Belardinelli, A.
Benni, M.
Tazzari, P. L.
Pagliaro, P. - Abstract:
- <abstract abstract-type="main" id="vox12033-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="vox12033-sec-0001" sec-type="section"> <title>Background and Objectives</title> <p>The haemoglobin level of prospective blood donors is usually performed on blood obtained by from the finger pulp by fingerstick with a lancet and filling a capillary tube with a sample. New noninvasive methods are now available for rapid, noninvasive predonation haemoglobin screening.</p> </sec> <sec id="vox12033-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Prospective blood donors at our blood centre were tested, in two different trials, as follows: by the NBM 200 (OrSense) test (<italic>n </italic>= 445 donors) and by the Pronto‐7 (Masimo) test (<italic>n </italic>= 463 donors). The haemoglobin values of each trial and the haemoglobin of finger pulp blood obtained by fingerstick with a lancet (HemoCue) were compared with the haemoglobin values obtained from a venous sample on a Cell Counter (Beckman Coulter).</p> </sec> <sec id="vox12033-sec-0003" sec-type="section"> <title>Results</title> <p>Comparison of Beckman Coulter Cell Counter and OrSense and results showed a bias of 0·29 g/dl, the standard deviation of the differences (SDD) of 0·98 and 95% limits of agreement from −1·64 to 2·21, using Bland and Altman statistical methodology. Comparison of Masimo and Beckman Coulter Cell Counter results showed a bias of −0·53 g/dl, SDD of 1·04 and 95% limits<abstract abstract-type="main" id="vox12033-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="vox12033-sec-0001" sec-type="section"> <title>Background and Objectives</title> <p>The haemoglobin level of prospective blood donors is usually performed on blood obtained by from the finger pulp by fingerstick with a lancet and filling a capillary tube with a sample. New noninvasive methods are now available for rapid, noninvasive predonation haemoglobin screening.</p> </sec> <sec id="vox12033-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Prospective blood donors at our blood centre were tested, in two different trials, as follows: by the NBM 200 (OrSense) test (<italic>n </italic>= 445 donors) and by the Pronto‐7 (Masimo) test (<italic>n </italic>= 463 donors). The haemoglobin values of each trial and the haemoglobin of finger pulp blood obtained by fingerstick with a lancet (HemoCue) were compared with the haemoglobin values obtained from a venous sample on a Cell Counter (Beckman Coulter).</p> </sec> <sec id="vox12033-sec-0003" sec-type="section"> <title>Results</title> <p>Comparison of Beckman Coulter Cell Counter and OrSense and results showed a bias of 0·29 g/dl, the standard deviation of the differences (SDD) of 0·98 and 95% limits of agreement from −1·64 to 2·21, using Bland and Altman statistical methodology. Comparison of Masimo and Beckman Coulter Cell Counter results showed a bias of −0·53 g/dl, SDD of 1·04 and 95% limits of agreement from −2·57 to 1·51. Cumulative analysis of all 908 donors, as tested by the usual fingerstick test showed a bias of 0·83 g/dl, SDD of 0·70 and 95% limits of agreement from −0·54 to 2·20 compared with the Coulter Cell Counter. Compared with the Coulter Counter, the specificity of the methods was 99·5% for fingerstick, 97% for OrSense and 83% for Massimo, and the sensitivity was 99, 98 and 93%, respectively.</p> </sec> <sec id="vox12033-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Analysis of finger pulp blood by either direct sampling by fingerstick and Hemocue, or by noninvasive haemoglobin tests does not replicate the results of cell counter analysis of venous samples. Compared with fingerstick, noninvasive haemoglobin tests eliminate pain and reduce stress, but have a lower level of specificity and sensitivity.</p> </sec> </abstract> … (more)
- Is Part Of:
- Vox sanguinis. Volume 105:Issue 2(2013)
- Journal:
- Vox sanguinis
- Issue:
- Volume 105:Issue 2(2013)
- Issue Display:
- Volume 105, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 105
- Issue:
- 2
- Issue Sort Value:
- 2013-0105-0002-0000
- Page Start:
- 116
- Page End:
- 120
- Publication Date:
- 2013-04-19
- Subjects:
- Blood -- Periodicals
Blood -- Transfusion -- Periodicals
Immunohematology -- Periodicals
Immunopathology -- Periodicals
615.39 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1423-0410 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=vox ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/vox.12033 ↗
- Languages:
- English
- ISSNs:
- 0042-9007
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9258.700000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4297.xml