Use of a Porous Polyethylene Lid Spacer for Management of Eyelid Retraction in Patients with Boston Type II Keratoprosthesis. (August 2013)
- Record Type:
- Journal Article
- Title:
- Use of a Porous Polyethylene Lid Spacer for Management of Eyelid Retraction in Patients with Boston Type II Keratoprosthesis. (August 2013)
- Main Title:
- Use of a Porous Polyethylene Lid Spacer for Management of Eyelid Retraction in Patients with Boston Type II Keratoprosthesis
- Authors:
- Sivaraman, Kavitha R.
Aakalu, Vinay K.
Sajja, Kiran
Cortina, Maria Soledad
de la Cruz, Jose
Setabutr, Pete - Abstract:
- <abstract> <title>Abstract</title> <p> <italic>Purpose</italic>: To report a novel application of a porous polyethylene implant for lid stabilization and management of eyelid retraction in a patient with an exposed Boston Keratoprosthesis Type II.</p> <p> <italic>Methods</italic>: A 54-year-old woman with a history of mucous membrane pemphigoid and failed penetrating keratoplasty of the left eye underwent implantation of a Boston Keratoprosthesis (KPro) Type II along with permanent surgical fusion of the upper and lower lids of the left eye in January 2010. At one month follow-up, significant retraction of the lower lid around the inferior margin of the optic was noted, resulting in partial exposure of the keratoprosthesis. The patient subsequently underwent left lower eyelid reconstruction with a porous polyethylene implant to ensure coverage and stability of the KPro.</p> <p> <italic>Results</italic>: Eyelid reconstruction using a porous polyethylene implant resulted in stable retention of the KPro Type II for over 2 years.</p> <p> <italic>Conclusion</italic>: In patients with Boston KPro Type II in the setting of severe cicatrizing ocular surface disease, the use of a porous polyethylene implant during eyelid reconstruction around the KPro optic may aid in maintaining eyelid integrity and improving KPro stability and longevity.</p> </abstract>
- Is Part Of:
- Orbit. Volume 32:Number 4(2013)
- Journal:
- Orbit
- Issue:
- Volume 32:Number 4(2013)
- Issue Display:
- Volume 32, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 32
- Issue:
- 4
- Issue Sort Value:
- 2013-0032-0004-0000
- Page Start:
- 247
- Page End:
- 249
- Publication Date:
- 2013-08
- Subjects:
- Eye-sockets -- Surgery -- Periodicals
Eye-sockets -- Diseases -- Periodicals
Orbit -- surgery -- Periodicals
Orbital Diseases -- Periodicals
617.7 - Journal URLs:
- http://informahealthcare.com/loi/orb ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/01676830.asp ↗ - DOI:
- 10.3109/01676830.2013.788664 ↗
- Languages:
- English
- ISSNs:
- 0167-6830
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6277.869600
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3379.xml