Diagnostic yield of combined bronchoscopy and endobronchial ultrasonography, under LungPoint guidance for small peripheral pulmonary lesions. Issue 5 (21st June 2013)
- Record Type:
- Journal Article
- Title:
- Diagnostic yield of combined bronchoscopy and endobronchial ultrasonography, under LungPoint guidance for small peripheral pulmonary lesions. Issue 5 (21st June 2013)
- Main Title:
- Diagnostic yield of combined bronchoscopy and endobronchial ultrasonography, under LungPoint guidance for small peripheral pulmonary lesions
- Authors:
- Tamiya, Motohiro
Okamoto, Norio
Sasada, Shinji
Shiroyama, Takayuki
Morishita, Naoko
Suzuki, Hidekazu
Yoshida, Emi
Hirashima, Tomonori
Kawahara, Kunimitu
Kawase, Ichiro - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="resp12095-sec-0001" sec-type="section"> <title>Background and objective</title> <p>The yield of biopsy performed during bronchoscopy is reduced if the lesion is smaller than 30 mm. We evaluated the performance of a new diagnostic technique combining endobronchial ultrasonography with a guide sheath (EBUS‐GS) and a virtual bronchoscopic navigation system, LungPoint (Broncus Technologies, Inc., Mountain View, CA, USA), for the diagnosis of small (≤30 mm) peripheral pulmonary lesions (PPL).</p> </sec> <sec id="resp12095-sec-0002" sec-type="section"> <title>Methods</title> <p>Between May 2011 and December 2011, we recruited 68 consecutive patients presenting with a PPL 30 mm or less in diameter determined by chest computed tomography. We used the LungPoint system before bronchoscopy to identify the bronchus into which the bronchoscope should be advanced. We used a thin bronchoscope. EBUS‐GS was performed using an endoscope ultrasonography system equipped with a 20‐MHz mechanical radial‐type probe. We used a guide sheath with an external diameter of 1.95 mm, thin forceps and brushing.</p> </sec> <sec id="resp12095-sec-0003" sec-type="section"> <title>Results</title> <p>The diagnostic yield of the 68 PPL was 77.9%; it was 83.7% and 68.0% for the malignant and benign lesions, respectively. Notably, three cases were diagnosed by transbronchial needle‐aspiration cytology alone. Univariate and multivariate analyses<abstract abstract-type="main"> <title>Abstract</title> <sec id="resp12095-sec-0001" sec-type="section"> <title>Background and objective</title> <p>The yield of biopsy performed during bronchoscopy is reduced if the lesion is smaller than 30 mm. We evaluated the performance of a new diagnostic technique combining endobronchial ultrasonography with a guide sheath (EBUS‐GS) and a virtual bronchoscopic navigation system, LungPoint (Broncus Technologies, Inc., Mountain View, CA, USA), for the diagnosis of small (≤30 mm) peripheral pulmonary lesions (PPL).</p> </sec> <sec id="resp12095-sec-0002" sec-type="section"> <title>Methods</title> <p>Between May 2011 and December 2011, we recruited 68 consecutive patients presenting with a PPL 30 mm or less in diameter determined by chest computed tomography. We used the LungPoint system before bronchoscopy to identify the bronchus into which the bronchoscope should be advanced. We used a thin bronchoscope. EBUS‐GS was performed using an endoscope ultrasonography system equipped with a 20‐MHz mechanical radial‐type probe. We used a guide sheath with an external diameter of 1.95 mm, thin forceps and brushing.</p> </sec> <sec id="resp12095-sec-0003" sec-type="section"> <title>Results</title> <p>The diagnostic yield of the 68 PPL was 77.9%; it was 83.7% and 68.0% for the malignant and benign lesions, respectively. Notably, three cases were diagnosed by transbronchial needle‐aspiration cytology alone. Univariate and multivariate analyses showed that the EBUS probe localization was the most significant contributor to successful diagnosis (diagnostic yield: within vs adjacent to the lesion = 92.1% vs 60.0%, respectively; <italic>P</italic> = 0.004 and <italic>P</italic> = 0.003, respectively).</p> </sec> <sec id="resp12095-sec-0004" sec-type="section"> <title>Conclusions</title> <p>The combination of EBUS‐GS and LungPoint was useful for diagnosing small PPL.</p> </sec> </abstract> … (more)
- Is Part Of:
- Respirology. Volume 18:Issue 5(2013)
- Journal:
- Respirology
- Issue:
- Volume 18:Issue 5(2013)
- Issue Display:
- Volume 18, Issue 5 (2013)
- Year:
- 2013
- Volume:
- 18
- Issue:
- 5
- Issue Sort Value:
- 2013-0018-0005-0000
- Page Start:
- 834
- Page End:
- 839
- Publication Date:
- 2013-06-21
- Subjects:
- Respiratory organs -- Diseases -- Periodicals
Respiratory organs -- Periodicals
612.2 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=res ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/resp.12095 ↗
- Languages:
- English
- ISSNs:
- 1323-7799
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7777.666000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4140.xml