A regional haemovigilance retrospective study of four types of therapeutic plasma in a ten‐year survey period in France. Issue 4 (7th January 2013)
- Record Type:
- Journal Article
- Title:
- A regional haemovigilance retrospective study of four types of therapeutic plasma in a ten‐year survey period in France. Issue 4 (7th January 2013)
- Main Title:
- A regional haemovigilance retrospective study of four types of therapeutic plasma in a ten‐year survey period in France
- Authors:
- Bost, V.
Odent‐Malaure, H.
Chavarin, P.
Benamara, H.
Fabrigli, P.
Garraud, O. - Abstract:
- <abstract abstract-type="main" id="vox12007-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="vox12007-sec-0001" sec-type="section"> <title>Background and objectives</title> <p>Our objective was to compare the frequency of adverse events (AEs) due to any of the 4 types of fresh‐frozen plasma (FFP) prepared and delivered by the French Blood Establishment (EFS) over a 10‐year period. Surveillance of AEs and vigilance was performed according to a homogeneous policy. The four types of FFP comprised of one type (methylene blue [MB) that was stopped since then and of another type [amotosalen (AI)] that was recently introduced, along with two conventional products [quarantine (Q) and solvent–detergent (SD)].</p> </sec> <sec id="vox12007-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>This is a retrospective study based on the national AE reporting database and on the regional database system for deliveries. AEs recorded after the delivery of 1 of the 4 types of FFP were pairwise compared, with appropriate statistical corrections.</p> </sec> <sec id="vox12007-sec-0003" sec-type="section"> <title>Results</title> <p>105 964 FFP units were delivered (38·4% Q, 17·9% SD, 9·7% MB and 34% AI).</p> <p>Statistical comparisons of AEs identified only a difference in AE rates between quarantine and solvent–detergent plasma.</p> </sec> <sec id="vox12007-sec-0004" sec-type="section"> <title>Conclusions</title> <p>FFP was confirmed to be extremely safe<abstract abstract-type="main" id="vox12007-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="vox12007-sec-0001" sec-type="section"> <title>Background and objectives</title> <p>Our objective was to compare the frequency of adverse events (AEs) due to any of the 4 types of fresh‐frozen plasma (FFP) prepared and delivered by the French Blood Establishment (EFS) over a 10‐year period. Surveillance of AEs and vigilance was performed according to a homogeneous policy. The four types of FFP comprised of one type (methylene blue [MB) that was stopped since then and of another type [amotosalen (AI)] that was recently introduced, along with two conventional products [quarantine (Q) and solvent–detergent (SD)].</p> </sec> <sec id="vox12007-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>This is a retrospective study based on the national AE reporting database and on the regional database system for deliveries. AEs recorded after the delivery of 1 of the 4 types of FFP were pairwise compared, with appropriate statistical corrections.</p> </sec> <sec id="vox12007-sec-0003" sec-type="section"> <title>Results</title> <p>105 964 FFP units were delivered (38·4% Q, 17·9% SD, 9·7% MB and 34% AI).</p> <p>Statistical comparisons of AEs identified only a difference in AE rates between quarantine and solvent–detergent plasma.</p> </sec> <sec id="vox12007-sec-0004" sec-type="section"> <title>Conclusions</title> <p>FFP was confirmed to be extremely safe in general, especially if one considers 'severe' AEs. All types of FFP were associated with extremely low occurrences of AEs. Q, SD, MB and AI led, respectively, to 7·14, 4·86, 1·05 and 4·16 AEs per 10 000 deliveries.</p> </sec> </abstract> … (more)
- Is Part Of:
- Vox sanguinis. Volume 104:Issue 4(2013)
- Journal:
- Vox sanguinis
- Issue:
- Volume 104:Issue 4(2013)
- Issue Display:
- Volume 104, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 104
- Issue:
- 4
- Issue Sort Value:
- 2013-0104-0004-0000
- Page Start:
- 337
- Page End:
- 341
- Publication Date:
- 2013-01-07
- Subjects:
- Blood -- Periodicals
Blood -- Transfusion -- Periodicals
Immunohematology -- Periodicals
Immunopathology -- Periodicals
615.39 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1423-0410 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=vox ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/vox.12007 ↗
- Languages:
- English
- ISSNs:
- 0042-9007
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9258.700000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3839.xml