Determination of docetaxel in rat plasma and its application in the comparative pharmacokinetics of Taxotere and SID530, a novel docetaxel formulation with hydroxypropyl‐β‐cyclodextrin. (27th July 2012)
- Record Type:
- Journal Article
- Title:
- Determination of docetaxel in rat plasma and its application in the comparative pharmacokinetics of Taxotere and SID530, a novel docetaxel formulation with hydroxypropyl‐β‐cyclodextrin. (27th July 2012)
- Main Title:
- Determination of docetaxel in rat plasma and its application in the comparative pharmacokinetics of Taxotere and SID530, a novel docetaxel formulation with hydroxypropyl‐β‐cyclodextrin
- Authors:
- Kim, Tae Kon
Kim, In Sook
Yoo, Hye Hyun - Abstract:
- <abstract abstract-type="main"> <title>ABSTRACT</title> <p>In this study, a sensitive, simple and reliable method for the quantification of docetaxel in rat plasma was developed and validated using liquid chromatography–tandem mass spectrometry (LC‐MS/MS). The plasma samples were prepared by protein precipitation, and paclitaxel was used as an internal standard (IS). Chromatographic separation was achieved using a Gemini C<sub>18</sub> column (2.0 × 150 mm, 5 µm) with a mobile phase consisting of 0.1% formic acid–acetonitrile (30:70, v/v). The precursor–product ion pairs used for multiple reaction monitoring were <italic>m/z</italic> 808.5 → 527.5 (docetaxel) and <italic>m/z</italic> 854.2 → 286.5 (IS, paclitaxel). A calibration curve for docetaxel was constructed over the range 1–1000 ng/mL. The developed method was specific, precise and accurate, and no matrix effect was observed. The validated method was applied in a comparative pharmacokinetic study in which two docetaxel formulations, SID530, a new parenteral formulation of docetaxel with hydroxypropyl‐<italic>β</italic>‐cyclodextrin (HP‐<italic>β</italic>‐CD), and Taxotere, were administered to rats at a dose of 5 mg/kg. For SID530 and Taxotere, the mean <italic>C</italic><sub>0</sub> values were 1494 and 1818 ng/mL, respectively, and the AUC<sub>last</sub> values were 837 and 755 h ng/mL, respectively. These two formulations did not show any statistical differences with regard to the pharmacokinetic parameters, thus<abstract abstract-type="main"> <title>ABSTRACT</title> <p>In this study, a sensitive, simple and reliable method for the quantification of docetaxel in rat plasma was developed and validated using liquid chromatography–tandem mass spectrometry (LC‐MS/MS). The plasma samples were prepared by protein precipitation, and paclitaxel was used as an internal standard (IS). Chromatographic separation was achieved using a Gemini C<sub>18</sub> column (2.0 × 150 mm, 5 µm) with a mobile phase consisting of 0.1% formic acid–acetonitrile (30:70, v/v). The precursor–product ion pairs used for multiple reaction monitoring were <italic>m/z</italic> 808.5 → 527.5 (docetaxel) and <italic>m/z</italic> 854.2 → 286.5 (IS, paclitaxel). A calibration curve for docetaxel was constructed over the range 1–1000 ng/mL. The developed method was specific, precise and accurate, and no matrix effect was observed. The validated method was applied in a comparative pharmacokinetic study in which two docetaxel formulations, SID530, a new parenteral formulation of docetaxel with hydroxypropyl‐<italic>β</italic>‐cyclodextrin (HP‐<italic>β</italic>‐CD), and Taxotere, were administered to rats at a dose of 5 mg/kg. For SID530 and Taxotere, the mean <italic>C</italic><sub>0</sub> values were 1494 and 1818 ng/mL, respectively, and the AUC<sub>last</sub> values were 837 and 755 h ng/mL, respectively. These two formulations did not show any statistical differences with regard to the pharmacokinetic parameters, thus establishing that the SID530 and Taxotere products are pharmacokinetically comparable in male rats. Copyright © 2012 John Wiley &amp; Sons, Ltd.</p> </abstract> … (more)
- Is Part Of:
- Biomedical chromatography. Volume 27:Number 3(2013:Mar.)
- Journal:
- Biomedical chromatography
- Issue:
- Volume 27:Number 3(2013:Mar.)
- Issue Display:
- Volume 27, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 27
- Issue:
- 3
- Issue Sort Value:
- 2013-0027-0003-0000
- Page Start:
- 306
- Page End:
- 310
- Publication Date:
- 2012-07-27
- Subjects:
- Chromatographic analysis -- Periodicals
Biology -- Periodicals
Medicine -- Periodicals
Biology -- Periodicals
Chromatography -- methods -- Periodicals
Medicine -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/bmc.2792 ↗
- Languages:
- English
- ISSNs:
- 0269-3879
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.758000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3324.xml