Continuous glucose monitoring. (2018)
- Record Type:
- Book
- Title:
- Continuous glucose monitoring. (2018)
- Main Title:
- Continuous glucose monitoring
- Further Information:
- Note: Weiping Jia, editor.
- Editors:
- Jia, Weiping
- Contents:
- Intro; Foreword 1; Foreword 2; Preface; Contents; About the Editor and Associate Editors; Contributors; 1: Determination of Glucose and Continuous Glucose Monitoring; 1.1 Metabolism and Regulation of Glucose; 1.1.1 Glucose Metabolism; 1.1.2 Glucose Regulation; 1.2 Detection of Interstitial Fluid Glucose Concentration and Its Clinical Significance; 1.3 Principle and Classification of CGM Technology; 1.4 Different Glucose Concentration Displayed in Human Body; 1.4.1 Glucose Concentrations in Three Major Types of Blood Vessels; 1.4.1.1 Venous Blood Glucose. 1.4.1.2 Arterial Blood Glucose1.4.1.3 Capillary Blood Glucose; 1.4.2 Glucose Concentrations in Plasma and Serum; 1.4.2.1 Plasma Glucose; 1.4.2.2 Serum Glucose; 1.4.2.3 Comparison of Plasma Versus Serum Glucose; 1.4.2.4 Comparison of Plasma Versus Whole Blood Glucose; 1.4.2.5 Urine Glucose; 1.4.2.6 Cerebrospinal Fluid (CSF) Glucose; 1.4.2.7 Salivary Glucose; 1.4.2.8 Tear Glucose; 1.4.3 Glycemic Parameters Reflecting Different Time Periods; References; 2: Introduction of Continuous Glucose Monitoring Technology; 2.1 Development of CGM Technology. 2.2 Technical Characteristics of CGM System2.2.1 Medtronic Inc.; 2.2.2 Dexcom Inc.; 2.2.3 Abbott Inc.; References; 3: Accuracy Assessment of Continuous Glucose Monitoring Technology; 3.1 Accuracy Assessment Methods Commonly Used in Clinical Practice; 3.2 Accuracy Assessment Methods for CGM Technology; 3.3 Accuracy Assessment of CGM Monitoring Results; 3.4 Factors Affecting theIntro; Foreword 1; Foreword 2; Preface; Contents; About the Editor and Associate Editors; Contributors; 1: Determination of Glucose and Continuous Glucose Monitoring; 1.1 Metabolism and Regulation of Glucose; 1.1.1 Glucose Metabolism; 1.1.2 Glucose Regulation; 1.2 Detection of Interstitial Fluid Glucose Concentration and Its Clinical Significance; 1.3 Principle and Classification of CGM Technology; 1.4 Different Glucose Concentration Displayed in Human Body; 1.4.1 Glucose Concentrations in Three Major Types of Blood Vessels; 1.4.1.1 Venous Blood Glucose. 1.4.1.2 Arterial Blood Glucose1.4.1.3 Capillary Blood Glucose; 1.4.2 Glucose Concentrations in Plasma and Serum; 1.4.2.1 Plasma Glucose; 1.4.2.2 Serum Glucose; 1.4.2.3 Comparison of Plasma Versus Serum Glucose; 1.4.2.4 Comparison of Plasma Versus Whole Blood Glucose; 1.4.2.5 Urine Glucose; 1.4.2.6 Cerebrospinal Fluid (CSF) Glucose; 1.4.2.7 Salivary Glucose; 1.4.2.8 Tear Glucose; 1.4.3 Glycemic Parameters Reflecting Different Time Periods; References; 2: Introduction of Continuous Glucose Monitoring Technology; 2.1 Development of CGM Technology. 2.2 Technical Characteristics of CGM System2.2.1 Medtronic Inc.; 2.2.2 Dexcom Inc.; 2.2.3 Abbott Inc.; References; 3: Accuracy Assessment of Continuous Glucose Monitoring Technology; 3.1 Accuracy Assessment Methods Commonly Used in Clinical Practice; 3.2 Accuracy Assessment Methods for CGM Technology; 3.3 Accuracy Assessment of CGM Monitoring Results; 3.4 Factors Affecting the Accuracy of CGM Measurements; References; 4: Operation Standards for Continuous Glucose Monitoring; 4.1 Operation Specifications for Medtronic CGM Systems; 4.2 Sensor Implantation Site. 4.3 Implantation of Glucose Sensor4.4 Sensor Initialization and Calibration; 4.5 Troubleshooting; References; 5: Methods for Interpreting Continuous Glucose Monitoring Graphs; 5.1 Basic Principles for Interpretation of a Retrospective CGM Report; 5.1.1 Interpretation of Nocturnal Blood Glucose; 5.1.2 Interpretation of Preprandial Blood Glucose; 5.1.3 Interpretation of Postprandial Blood Glucose; 5.2 Basic Principles for Interpretation of a Real-Time CGM Report; References; 6: Definition and Clinical Significance of Continuous Glucose Monitoring Parameters. 6.1 Parameters Reflecting Mean Blood Glucose (MBG) and Their Clinical Significance6.2 Parameters Reflecting Glycemic Variability and Their Clinical Significance; 6.2.1 Parameters Reflecting Intraday Glycemic Variability; 6.2.1.1 SDBG; 6.2.1.2 CV; 6.2.1.3 LAGE; 6.2.1.4 MAGE; 6.2.1.5 M-value; 6.2.1.6 J-index; 6.2.1.7 Continuous Overlapping Net Glycemic Action over an n-Hour Period (CONGAn); 6.2.1.8 Mean Absolute Glucose (MAG); 6.2.2 Parameters Reflecting Inter-day Glycemic Variability; 6.2.2.1 CV-FPG; 6.2.2.2 MODD; 6.2.3 Parameters Reflecting Postprandial Glycemic Variability. … (more)
- Publisher Details:
- Singapore : Springer
- Publication Date:
- 2018
- Extent:
- 1 online resource
- Subjects:
- 616.07/561
Blood sugar monitoring
HEALTH & FITNESS -- Diseases -- General
MEDICAL -- Clinical Medicine
MEDICAL -- Diseases
MEDICAL -- Evidence-Based Medicine
MEDICAL -- Internal Medicine
Blood sugar monitoring
Blood Glucose Self-Monitoring -- methods
Glucose Metabolism Disorders -- therapy
Diabetes Mellitus -- blood
Diabetes
Electronic books - Languages:
- English
- ISBNs:
- 9789811070747
9811070741 - Related ISBNs:
- 9789811070730
9811070733 - Notes:
- Note: Includes bibliographical references.
Note: Online resource; title from PDF title page (Ebsco, viewed August 13, 2018). - Access Rights:
- Legal Deposit; Only available on premises controlled by the deposit library and to one user at any one time; The Legal Deposit Libraries (Non-Print Works) Regulations (UK).
- Access Usage:
- Restricted: Printing from this resource is governed by The Legal Deposit Libraries (Non-Print Works) Regulations (UK) and UK copyright law currently in force.
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD.DS.399120
- Ingest File:
- 02_427.xml